4.3.2 Gap/Black Mark Sensor Calibration, Self-Test, and Entering Dump Mode

During the calibration of the Gap/Black Mark Sensor, the printer will detect the label length, print
the internal configuration (self-test), and then enter the dump mode.
Mark Sensor if the sensor's settings used in the last print job are not suitable for the current print
job.
To calibrate the Gap/Black Mark Sensor:
1. Turn off the printer.
2. Press and hold the Feed/Pause Button, and then turn on the printer.
3. Release the button when the LED is flashing in amber.
Note
The LED color will change as follows:
Amber  red (5 times)  amber (5 times)  green (5 times)  green/amber (5 times) 
red/amber (5 times)  green (lit)
4. The printer calibrates the sensor and detects the label length, prints the internal settings, and
then enters the dump mode.
Note
To select the sensor for calibration, send the correct command to the printer:
For the Gap Sensor: send the GAP command
For the Black Mark Sensor: send the BLINE command
For more information about the available commands, see the FBPL Command Reference
Manual.