Hitachi Compute Blade Series Update Manual page 71

Logical partitioning manager version upgrade/revision
Table of Contents

Advertisement

Manual shutdown by Blade Server Manager (BSM)
The following message may appear when manually shutting down the LPAR manager by
BSM.
+-----------------------------------------------+
| An error occurred in the power-off request to |
| LP_XXXXXXXXX(LP)
| KASM21805-E 029
+-----------------------------------------------+
When this message appears, it is possible that LP firmware is still being updated.
If it is still being updated, please shutdown LPAR manager when the update operation is
completed.
LPAR manager does not start when rebooting server blade
At the last step of firmware update by using LP Maintenance Tool, the server blade is
rebooted to start the LPAR manager in new firmware version and/or revision. However, in
the event that rebooting the server blade does not boot LPAR manager, start a remote
console and check the status of the server blade.
Check if the remote console shows the following message. When the following message
appears, take actions according to the "What to do".
Message Content
LP Loader detected enable H/W Memory Dump setting in this system. [INFO:XX]
Please set H/W Memory Dump setting to disable.
Explanation
LPAR manager cannot boot due to the Enabled hardware memory dump setting.
What to do
Set Disabled in the [hardware memory dump] setting, and turn on power of the
server blade again.
Static Version Upgrade/Revision Update by LP Maintenance Tool
Hitachi Compute Blade Logical partitioning manager Version Upgrade / Revision Update Guide
|
|
3-15