Chapter 1 Overview; Characteristics Of Bbu; Specification - NEC N8103-136 User Manual

Additional battery
Table of Contents

Advertisement

16

Chapter 1 Overview

First read this chapter if you use the N8103-136 Additional DAC Battery (called Battery
Backup Unit=BBU) for the first time.
This chapter describes the characteristics and configuration of the BBU-Plus3 and outlines
the additional battery installation job.

1. Characteristics of BBU

The BBU is an additional battery exclusively used for the N8103-134 RAID Controller
(called RAID Controller hereafter).
Connecting the BBU to the RAID Controller can prevent data from being lost due to an
accident including instantaneous power interruption (in the WriteBack mode).
Backup of data in SDRAMs on RAID Controller for up to 72 hours
Improvement of reliability in WriteBack mode
Use of rechargeable lithium ion battery

2. Specification

Item
Maximum data backup time
Outer dimension
Weight
Power consumption
Operating
Temperature
environment
Humidity
Storage
Temperature
environment
Humidity
Life (battery back)
Specification
72 hours
52 (width) × 55.6 (depth) x
14.1 (height) mm
Approx. 0.10 kg
1.92 W
10°C to 35°C
20% to 80%
0°C to 35°C
20% to 80%
About 2 years
Remarks
Full charging
(Even charge completion
is about 10 hours.)
Excluding battery cable
Without condensation
Without condensation
Varies depending on
operating environment
and boundary conditions