C. Rotate the right hand knob clockwise to select the next set of CAM1 IP ADDRESS values, using the knobs
beneath the number that you want to change, set the address values required.
D. Rotate the right hand knob clockwise to highlight the PORT number, using the knob beneath the PORT
number set the number to be 49152.
E. Press the knob below CAM1 INF UPLOAD (push). A popup saying COMPLETE will appear. Press the 3
knob from the left.
F. Press the MENU button to exit.
4.5 Setup of Panasonic VariCam LT for use with DTS1810U Basestation ERI.
A. On the VLT Control Panel press the MENU button.
B. Highlight and select LAN PROPERTY.
C. Select DCHP and set to DISABLE.
D. Select IP ADDRESS and set to the required address. In this example, 192.168.1.002. This must be the same
as address set in the ERI - IP Adjust: - CAM Adjust: menu. Select OK when finished.
E. Select SUBNET MASK and set to the required value i.e 255.255.255.0. This must be the same as set in the
ERI - IP Adjust: - menu. Select OK when finished.
F. Select DEFAULT GATEWAY and set to the required address i.e 192.168.1.1. This must be the same as set in
the ERI - IP Adjust: menu. Select OK when finished
G. Highlight EXIT and select it. The Network will restart.
H. Highlight and select NETWORK SEL and set to LAN.
I. Highlight EXIT and select it.
J. To set up a User Account Refer to Panasonic 'Multicam White Paper'
K. NOTE: for ROP operation select SCENE 1 under Main Colour Setting.
5. VLT Settings for Cine Live 4K.
5.1 Notes on Video Setting.
Resolution: 3840 x 2160.
Frequency: 50/59.94P
SDI OUTPUT: Ensure Processed RAW not RAW is selected.
Codec: AVC-I4KLT