PARAMETERS
(2) How to set the digital input value as the torque command value
When "9999" is set in Pr. 448, the input signal is considered as a torque command value.
For example, the torque command value when the input signal is 190H (400) is 400% as shown below.
Even if a value higher than 190H (400) is input, the torque command value is clamped at 400%.
7FFF
(7FF
H
38
Torque command value
400%
190
H
H
)
(400)
Most significant bit = 1
0
190
H
(400)
-400%
Most significant bit = 0
7FFF
H
Digital input signal
(7FF
)
H

Hide quick links: