1. Straight hydraulic fitting
13.
Secure 1 end of the valve hose to the 90°
hydraulic fitting connected to the back of the
solenoid valve with a worm-drive clamp.
14.
Slip a worm-drive clamp over the free end of
the valve hose, and secure the end of the valve
hose to the straight hydraulic fitting on the leak
detector tank.
15.
Use 2 worm-drive clamps to secure the overflow
hose to the leak detector tank and the hydraulic
tank
(Figure
3).
16.
Connect the delay time connector to the
connector on the wire harness (diesel model
only).
17.
Connect the solenoid valve connector to the
connector marked "Leak Detector Solenoid" on
the wire harness.
18.
Remove the plug from the main hydraulic tank
(Figure
9).
Figure 8
2. Leak detector tank
g016176
1. Remove plug from main
hydraulic tank here.
19.
Slide the O-ring onto the hydraulic-oil-level
sensor and install the sensor into the hydraulic
tank
(Figure
Important:
on each side of the nut that secures the
hydraulic oil level sensor points downward
(Figure
9).
20.
Connect the oil-level sensor connector to the
connector marked "Leak Detector Switch" on
the wire harness.
21.
Secure the leak detector tank onto the main
hydraulic tank with the 4 bolts, washers,
spacers, and rubber washers that you previously
removed.
22.
Torque the bolts to 3.4 to 6.7 N∙m (30 to 60 in-lb).
23.
Ensure that all the fittings are tight.
4

Completing the Installation

Parts needed for this procedure:
1
Plug
1
Dipstick
Procedure
1.
Remove and discard the breather and top off the
main hydraulic tank with hydraulic fluid
10).
5
Figure 9
2. Indicator arrow on nut (2)
9).
Ensure that the indicator arrow
g016177
(Figure

Advertisement