Toro 04730 Installation Instructions Manual page 6

Hydraulic fluid leak detector kit for greensmaster 3300/3400 series triflex traction unit

Advertisement

Figure 10
1. Plug (replaces the
breather)
2. Fill with hydraulic fluid to
top off the main hydraulic
tank here.
2.
Install a plug in place of the breather
3.
Trim the dipstick to the marked trim line shown
in
Figure
11. Ensure that the trimmed end is
smooth; deburr the end as needed.
Figure 11
1. 9.5 cm (3-3/4 inches)
2. Trim the dipstick here.
4.
Fill the leak detector tank according to the
characteristics of your leak detector tank, as
follows:
If your leak detector tank has a sight window:
g016178
3. Sight window
(Figure
10).
g236710
3. Appropriate hydraulic fluid
level
Fill the leak detector tank with hydraulic fluid
until the fluid level is at the middle of the
sight window.
If your leak detector tank does not have a
sight window:
Fill the leak detector tank with hydraulic fluid
until the fluid level is at the middle of the fill
marks on the dipstick; refer to
5.
Install the dipstick on the leak detector tank
(Figure
12).
1. Dipstick
6.
Install the console arm cover using the hex-head
screws that you previously removed.
7.
Connect the battery; refer to your machine
Operator's Manual.
6
Figure
Figure 12
2. Leak detector tank
11.
g236731

Advertisement