Performance Tests
PDH/DSn Internal Transmitter Clock Accuracy & Offset

E2 (8.448Mb/s) Frequency Accuracy

9 Select SIGNAL [8Mb/s] ; PATTERN [ALL 1's] on the
display.
10 Adjust the Frequency Counter ATTEN and Trigger Level to obtain a
stable reading and ensure that the frequency counter reading is
between 4223981Hz and 4224019Hz.
11 Select FREQUENCY OFFSET [+30PPM].
12 Adjust the Frequency Counter ATTEN and Trigger Level to obtain a
stable reading and ensure that the frequency counter reading is
between 4224107.5Hz and 4224291.5 Hz.
13 Select FREQUENCY OFFSET [-30PPM].
14 Adjust the Frequency Counter ATTEN and Trigger Level to obtain a
stable reading and ensure that the frequency counter reading is
between 4223854Hz and 4223892Hz.

E3 (34.368Mb/s) Frequency Accuracy

15 Select SIGNAL [34Mb/s] PATTERN [ALL 1's] on the
display.
16 Adjust the Frequency Counter ATTEN and Trigger Level to obtain a
stable reading and ensure that the frequency counter reading is
between 17183922.7Hz and 17184077.4Hz.
17 Select FREQUENCY OFFSET [+20PPM]
18 Adjust the Frequency Counter ATTEN and Trigger Level to obtain a
stable reading and ensure that the frequency counter reading is
between 17184266 and 17184421Hz.
19 Select FREQUENCY OFFSET [-20PPM]
20 Adjust the Frequency Counter ATTEN and Trigger Level to obtain a
stable reading and ensure that the frequency counter reading is
between 17183579Hz and 17183734Hz.
21 Select FREQUENCY OFFSET [USER OFFSET] [+100PPM]
22 Adjust the Frequency Counter ATTEN and Trigger Level to obtain a
stable reading and ensure that the frequency counter reading is
between 17185641Hz and 17185796Hz.
23 Select FREQUENCY OFFSET [USER OFFSET] [-100PPM]
3-10