CCPU_WinReset
Forces a restart of the Windows part of a MELIPC.
Format
short CCPU_WinReset(void)
Argument
None
Description
• Runs processing equivalent to when the WIN RESET switch of the MELIPC was operated and forces a restart of the
Windows part of the MELIPC.
• If this function is executed while file writing is occurring on the Windows part, data corruption or a file system error may
occur.
• To execute this function, it is necessary to allow a forced restart of the Windows part in the parameters. Otherwise, an error
occurs.
[Basic Parameters]  "Operation Related Settings" "Windows part forced restart"
• If the MELIPC shutdown function is run, and the MELIPC enters a state in which the power supply can be turned OFF, a
forced restart of the Windows part is not performed, and this function ends normally.
Return value
Return value
0(0000H)
-374(FE8AH)
For details on error codes, refer to the following section.
Page 116 Function error codes