85

Circuit diagram

This circuit diagram shows how the AGPS-11 kit is installed.
Drive
115/230 VAC
N
3AFE00374994

Start-up and validation

Action
Follow the safety instructions, see section
Safety instructions
on page
5.
Ensure that the drive can be run and stopped freely during the start-up.
Stop the drive (if running), switch the input power off and isolate the drive from the power line by a
disconnector.
Check the Prevention of unexpected start-up circuit connections against the circuit diagram.
Close the disconnector and switch the power on.
Test the operation of the Prevention of unexpected start-up function when the motor is stopped:
• Give a stop command for the drive (if running) and wait until the motor shaft is at standstill.
• Activate the Prevention of unexpected start-up function and give a start command for the drive.
• Ensure that the drive does not start and the motor stays at standstill.
• Deactivate the Prevention of unexpected start-up function.
Installation of the AGPS board (Prevention of unexpected start-up, +Q950)