8. FUNCTION TEST

Function Test
• Connect the Vacuum to a power outlet�
• Push the green button. A white lamp is lit up, and the compressor will start to build up pressure. It can take
around 30 seconds until the compressor has reached the correct pressure. (Note: if the correct pressure is main
tained the compressor won't engage)
• Put the Purge Setting button in Manual mode, and push the manual purge button.
• The purge should now clean the filter and the compressor should start to build pressure again until the correct
pressure is reached. If this doesn't happen see the Purge Fault Tracing section.
• The machine has power and is in stand-by mode.
• Turn the switch to the ON position and the Blower motor should engage. If this doesn't happen see the Blower
Motor Fault Tracing Section�