MEASUREMENT SETUP
Tuner FM
RF Generator
e.g. PM5326
Use a bandp ass filter to eliminate hum (50Hz,100H z) and distu rbance from the pilottone(19kHz,38k Hz).
Tuner A M (MW,LW)
RF G enerator
e.g. PM53 26
To a void atmosp heric interfer ence all AM- measurements have to b e carried out in a Faraday s cage.
Use a bandpass filter ( or at le ast a high pass filter with 250Hz) to eliminate hum ( 50Hz,100H z ).
CD
Use Audio Signal Disc SBC429 4822 397 30184
(repl aces test dis c 3)
DU T
L
R
Bandpass
DU T
250Hz-15kHz
e. g. 7122 707 48001
Bandpa ss
250 Hz-15kHz
DUT
e.g. 7122 707 48 001
Frame aer ial
e.g. 7122 707 89001
S/N and d istortion me ter
e.g. Sound Technol ogy ST1700B
LEVEL MET ER
e.g. Sennheiser UPM550
with FF-filter
1-3
LF Voltmeter
e.g. P M2534
S/N and distortion meter
e.g . Sound Tech nology ST1 700B
LF Voltmeter
e.g. PM2 534
S/N an d distortion meter
e.g. S ound Techn ology ST1700B
'

Advertisement