Troubleshooting

Problem
Does not heat up.
Steam does not come out.
Shots do not come out.
There is not enough steam.
The shots are weak.
Fabric is burned.
Iron turns off when placed
in the stand.
When iron is plugged in,
it switches to something
other than [OFF].
Questions about handling, cleaning, or repairing your iron
Contact the store from which the product was purchased.
Where to check
Power plug
SET / OFF button
Placement on the stand
Contact pins
Steam / Dry lever
Setting of the water tank
Shot button
SET / OFF button
Steam / Dry lever
Amount of water in the water tank
Plugged steam vents
A patch cloth was not used to fiber that
are sensitive to heat.
SET / OFF button
Too much starch was sprayed.
SET / OFF button
SET / OFF button
13
Refer to the following points if you
think something is wrong.
Solution
Plug the power plug completely into an electrical
outlet.
Change the setting to the temperature that is
most appropriate for the fabric.
Place the iron correctly on the stand.
Remove any foreign matter from the contact pins.
Set the Steam / Dry lever to [
Shower].
Press in until you hear a click.
Place the iron on the stand after it has charged,
and press the Shot button at intervals of about 2
to 5 seconds.
Set the temperature setting to [HIGH].
Set the Steam / Dry lever to [
Shower].
Hold the iron horizontally, set the Steam / Dry
lever in the [
Steam] or the [
tion, then press the Shot button
to do shots.
Add water up to the full mark.
Clean the steam vents.
Use a press cloth.
Change the setting to the temperature that is
most appropriate for the cloth.
Rinse away the starch with water from the cloth-
ing.
Reset the temperature setting.
When you finish using the iron, set the button to
[OFF].
If you unplug the iron without setting the button
to [OFF] and plug it in again, the settings stored in
the microcomputer may be used for the tempera-
ture setting.
Steam] or [
Steam] or [
Shower] posi-
several times