Siemens SIMATIC NET RUGGEDCOM RST2228 Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RST2228:

Advertisement

Quick Links

Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RST2228
Edition
08/2020
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RST2228

  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RST2228 Edition 08/2020 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RST2228 Communication Ports Technical Specifications Installation Manual Certification 08/2020 C79000-G8976-1359-10...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 5 Decommissioning and Disposal ................5 Cabling Recommendations ..................
  • Page 5 Table of Contents Technical Specifications ...................... 35 Power Supply Specifications ................35 Failsafe Alarm Relay Specifications ..............35 Supported Networking Standards ................ 35 Operating Environment ..................36 Mechanical Specifications ..................36 Dimension Drawings ................... 36 Certification ......................... 39 Approvals ......................39 6.1.1 CSA ........................
  • Page 6: Preface

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    Contacting Siemens • Submit SRs or check on the status of an existing SR • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 10: Introduction

    Reliability in Harsh Environments • Immunity to EMI and heavy electrical surges • Zero-Packet-Loss Technology • Supports Siemens FastConnect RJ45 Cabling System • -40 to 85 °C (-40 to 185 °F) operating temperature (fan-less) RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 11: Description

    Introduction 1.2 Description • Conformal coated printed circuit boards (optional) Description The RUGGEDCOM RST2228 features various ports, controls and indicator LEDs for connecting, configuring and troubleshooting the device. Orientation Options The RUGGEDCOM RST2228 is available in one of two options: • Option 1 Status panel, alarm LED, ACO Button, CLP port and USB console port are located on the front panel.
  • Page 12 Introduction 1.2 Description • Option 2 Status panel, alarm LED, ACO Button, CLP port and USB console port are located on the rear panel. Status Panel ACO Button CLP Port USB Console Port Failsafe Alarm Relay Terminal Block Power Terminal Block SFP/SFP+ Transceiver Sockets Media Modules Chassis Ground Terminal...
  • Page 13 Introduction 1.2 Description LEDs for 10GBase SFP+ Transceivers (Slot 0) Module Slot Locators LEDs for Module Ports Alarm Status LED Power Supply Status LEDs ACO Button Figure 1.3 Status Panel State Description P{number} Solid Link detected Blinking Link activity No link detected Solid An alarm condition exists No active alarm conditions exist...
  • Page 14: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials Chassis Ground Terminal Protects the device from power surges and accumulated static electricity. For information about grounding the device, refer to "Connecting Power (Page 15)". Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RST2228: Tools/Materials Purpose AC/DC power cord...
  • Page 15: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 16: Supported Fiber Optic Cables

    Introduction 1.5.3 Supported Fiber Optic Cables • Shielded/screened cabling can be used when required. Care should be taken to avoid the creation of ground loops with shielded cabling. 1.5.3 Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions. Cable Type Wavelength (nm) Modal Bandwidth Distance (m)
  • Page 17 Introduction 1.5.3 Supported Fiber Optic Cables RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 18: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 19: Unpacking The Device

    Visually inspect each item in the package for any physical damage. Verify all items are included. IMPORTANT If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RST2228 is designed for maximum mounting and display flexibility.
  • Page 20: Mounting The Device To A Rack

    Installing the Device 2.3.1 Mounting the Device to a Rack NOTICE Heat generated by the device is channeled outwards from the enclosure. As such, it is recommended that 2.5 cm (1 in) of space be maintained on all open sides of the device to allow for some convectional airflow.
  • Page 21: Mounting The Device To A Panel

    Installing the Device 2.3.2 Mounting the Device to a Panel to have the power supplies, management ports and LEDs accessible from the front. Note Since heat within the device is channeled to the enclosure, it is recommended that 1 rack-unit of space, or 44 mm (1.75 in), be kept empty above the device. This allows a small amount of convectional airflow.
  • Page 22: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay Place the device against the panel and align the adapters with the mounting holes. Screw Panel Adapter Figure 2.3 Panel Mounting Secure the adapters to the panel with M6 or #10-32 screws. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
  • Page 23 Installing the Device 2.4 Connecting the Failsafe Alarm Relay To connect the failsafe alarm relay, do the following: Connect the failsafe alarm relay terminal block to the device. The terminal block is available as either a screw-type terminal block or a pluggable terminal block. •...
  • Page 24: Connecting Power

    Installing the Device 2.5 Connecting Power Connecting Power The RUGGEDCOM RST2228 supports dual redundant AC and/or DC power supplies that can be installed in any combination. The RUGGEDCOM RST2228 can be equipped with either a screw-type or pluggable terminal block, which provides power to both power supplies. The screw-type terminal block is installed using Phillips screws and compression plates, allowing either bare wire connections or crimped terminal lugs.
  • Page 25 Installing the Device 2.5.1 Connecting High AC/DC Power CAUTION Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a DC power supply terminal block. Damage to the power supply may occur. Note The screw-type terminal block is installed using Phillips screws and compression plates, allowing either bare wire connections or crimped terminal lugs.
  • Page 26 Installing the Device 2.5.1 Connecting High AC/DC Power Connect the Line wire from the power source to the positive/live (+/L) terminal on the terminal block. Pluggable Terminal Block Screw-Type Terminal Block Positive/Line (+/L) Terminal for PS1 Chassis/Ground Terminal for PS1 Negative/Neutral (-/N) Terminal for PS1 Positive/Line (+/L) Terminal for PS2 Chassis/Ground Terminal for PS2 Negative/Neutral (-/N) Terminal for PS2...
  • Page 27: Connecting Low Dc Power

    Installing the Device 2.5.2 Connecting Low DC Power Connect the chassis ground screw to ground (Potential Earth). It is recommended to terminate the ground connection with an M3 ring or spade lug, and then torque to 1.7 N·m (15 lbf-in). M3 Screw M3 Ring Lug Figure 2.9 Chassis Ground Connection...
  • Page 28 Installing the Device 2.5.2 Connecting Low DC Power Connect the power supply terminal block to the device. Pluggable Terminal Block Screw-Type Terminal Block Figure 2.10 Assembling the Power Supply Terminal Block Connect the positive wire from the power source to the positive terminal on the terminal block.
  • Page 29: Wiring Examples

    Installing the Device 2.5.3 Wiring Examples For pluggable terminal blocks, install the safety cover. Figure 2.12 Assembling the Safety Cover Connect the ground terminal on the power source to the ground terminal on the device. M3 Screw M3 Ring Lug Figure 2.13 Chassis Ground Connection 2.5.3 Wiring Examples The following illustrate how to connect single and dual power supplies to the device.
  • Page 30 Installing the Device 2.5.3 Wiring Examples Figure 2.14 Single High AC/DC Power Supply Figure 2.15 Single Low DC Power Supply RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 31 Installing the Device 2.5.3 Wiring Examples Figure 2.16 Dual High AC/DC Power Supply Figure 2.17 Dual Low DC Power Supply RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 32 Installing the Device 2.5.3 Wiring Examples Figure 2.18 High AC/DC Power Supply and Low DC Power Supply RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 33 Installing the Device 2.5.3 Wiring Examples RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 34: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS Configuration Manual for the device.
  • Page 35: Configuring The Device

    Device Management 3.2 Configuring the Device Ethernet Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RST2228 console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RST2228 is https://- 192.168.0.1.
  • Page 36 Device Management 3.3 Inserting/Removing the CLP Removing the CLP To remove the CLP, do the following: NOTICE Configuration hazard – risk of data loss After uploading or downloading a file, allow at least twenty seconds before removing the CLP to ensure the data has been fully transferred. Insert a flat head screwdriver into the bottom portion of the CLP port, and gently pry the CLP out.
  • Page 37 Device Management 3.3 Inserting/Removing the CLP Installing the CLP To install the CLP, do the following: Remove the protective cover from the CLP port. Protective cover Figure 3.2 Installing the CLP Insert the CLP into the CLP port. RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 38: Communication Ports

    1 to 6 Field-replaceable modules SFP Transceivers The RUGGEDCOM RST2228 supports up to four Small Form-factor Pluggable (SFP) transceiver sockets, which are compatible with the wide array of SFP/SFP+ transceivers available from Siemens. Note RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 39 RUGGEDCOM SFP Transceiver Catalog [https://- support.industry.siemens.com/cs/ca/en/view/109482309]. NOTICE Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. SFP Transceiver...
  • Page 40: Available Modules

    Communication Ports 4.2 Available Modules Available Modules The following modules are available for use with the RUGGEDCOM RST2228. For more information about individual modules, refer to the RUGGEDCOM Modules Catalog for the device available online. Copper Ethernet Modules RUGGEDCOM RMM2973-4RJ45 Specifications Article Numbers Ports: 4 6GK6297-3RD00-4AB0...
  • Page 41: Installing/Removing Modules

    Communication Ports 4.3 Installing/Removing Modules Speed: 100/1000 Mbps 6GK6297-8SB00-2AAO (Standard) Protocol: HSR-PRP 6GK6297-8SB00-2AA1 (Conformal Coated) Blank Modules RUGGEDCOM RMM2931-4 Specifications Article Numbers Blank module 6GK6293-1BA00-4AA0 Installing/Removing Modules Upon installing a new media module in the device, all features associated with the module are available in RUGGEDCOM ROS. For more information, refer to the RUGGEDCOM ROS Configuration Manual for the device.
  • Page 42 Communication Ports 4.3 Installing/Removing Modules Pull the module from the chassis to disconnect it. Figure 4.2 Removing a Module Install a new module or a blank module (to prevent the ingress of dust and dirt). [Optional] If necessary, install the device in the rack. Connect power to the device.
  • Page 43 Communication Ports 4.3 Installing/Removing Modules RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 44: Technical Specifications

    Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the minimum input voltage for the power supply is provided at the power source. Note Use the internal fuse rating to determine the size of the external circuit breaker/fuse. Power Input Range Internal...
  • Page 45: Operating Environment

    Technical Specifications 5.4 Operating Environment 1000 10000 Parameter 10 Mbps Notes Mbps Mbps Mbps IEEE 802.1Q VLAN (Virtual LAN) ü ü ü ü IEEE 802.1p Priority levels ü ü ü ü Port-based network IEEE 802.1x ü ü ü ü access control IEEE 802.3  ...
  • Page 46 Technical Specifications 5.6 Dimension Drawings 446.0 Figure 5.1 Overall Dimensions RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 47 Technical Specifications 5.6 Dimension Drawings 462.2 43.6 23.5 Figure 5.2 Rack Mount Dimensions 43.6 462.2 23.5 Figure 5.3 Panel Mount Dimensions RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 48: Certification

    The device is marked with a CSA symbol that indicates compliance with both Canadian and U.S. requirements. 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: EN 60950-1 •...
  • Page 49: Tüv Süd

    Products with Respect to the Restriction of Hazardous Substances The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 50: Fda/Cdrh

    Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this device. 6.1.6 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.7...
  • Page 51: Rohs

    Certification 6.1.8 RoHS 6.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: • China RoHS 2...
  • Page 52 Certification 6.2 EMC and Environmental Type Tests • If the unit contains all fiber ports, the IEC 61850-3 and IEEE 1613 conformance is Class 2, during which no disturbance errors will occur. Test Description Test Levels Severity Levels IEC 61000-4-2 Enclosure Contact ±...
  • Page 53 5 kV (Fail-Safe   Relay Output) DC Power Ports 5 kV   AC Power Ports 5 kV   Siemens-specified severity levels EMC Immunity Type Tests per IEEE 1613 Description Test Levels Severity Levels Enclosure Contact ± 8 kV   Enclosure Air ±...
  • Page 54 Certification 6.2 EMC and Environmental Type Tests Description Test Levels Severity Levels AC Power Ports 2 kV   Damped Oscillating Enclosure Ports 100 A/m (peak) for 1 s Magnetic Field (100 kHz and 1 MHz) Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-1 Cold Temperature...
  • Page 55 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RST2228 Installation Manual, 08/2020, C79000-G8976-1359-10...
  • Page 56 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...