Remove Failed Power Supply - Fujitsu ETERNUS AB Series Maintaining Hardware

Hide thumbs Also See for ETERNUS AB Series:
Table of Contents

Advertisement

c) When you find the shelf with a red icon, select Show back of shelf.
d) Select either power supply.
e) On the Power Supplies and Fans tabs, look at the statuses of the power-fan canisters, the power
supplies, and the fans to determine which power supply must be replaced.
A component with a Failed status must be replaced.
Attention: If the second power supply canister in the shelf does not have Optimal status,
do not attempt to hot-swap the failed power supply. Instead, contact technical support for
assistance.
3. From the back of the storage array, look at the Attention LEDs to locate the power supply you need to
remove.
You must replace the power supply that has its Attention LED on.
Power LED: If it is solid green, the power supply is functioning correctly. If it is Off, the power
supply failed, the AC switch is turned off, the AC power cord is not properly installed, or the AC power cord
input voltage is not within margin (there is a problem at the source end of the AC power cord).
Attention LED: If it is solid amber, the power supply or its integrated fan has a fault.
What to do next
Go to
Remove failed power

Remove failed power supply

You remove a failed power supply so you can replace it with a new one. When you remove a power supply
(referred to in SANtricity System Manager as a power-fan canister), you turn off power, disconnect the power
cord, and slide the part out of the shelf.
Before you begin
• You have an ESD wristband, or you have taken other antistatic precautions.
Procedure
1. Unpack the new power supply, and set it on a level surface near the drive shelf.
Save all packing materials for use when returning the failed power supply.
2. Turn off the power supply and disconnect the power cables:
a) Turn off the power switch on the power supply.
b) Open the power cord retainer, and then unplug the power cord from the power supply.
c) Unplug the power cord from the power source.
3. Squeeze the latch on the power supply cam handle, and then open the cam handle to fully release the
power supply from the mid plane.
supply.