Download Print this page

Husqvarna BG 245 Operator's Manual page 17

Advertisement

To clean or replace the bearing for the
pressure plate (BG 245)
1. Remove the screw and washer.
2. Remove the blade assembly. Use a puller if the
blade assembly is not easy to remove.
3. Remove the pressure plate.
1071 - 001 - 11.12.2019
4. Remove the protection ring (A) and the needle
bearing (B).
A
5. Clean the surfaces of all parts and lubricate
carefully. Replace damaged parts.
6. Lubricate the needle bearing with grease. Refer to
Technical data on page 23 for correct type of
grease.
7. Assemble in the opposite sequence.
To clean or replace the bearing for the
pressure plate (BG 375, BG 475)
1. Remove the screw and washer.
2. Remove the blade assembly. Use a puller if the
blade assembly is not easy to remove.
B
17

Advertisement