Advertisement

Installing the Wired Controller
For Debris Blowers with Serial Numbers
31200000 to 315099999 (Model No.
44538, 44539, or 44542)
1. Disconnect the battery cables from the battery.
Note: Disconnect the negative-battery cable first, and
then disconnect the positive-battery cable.
2. Disconnect the wire harness from the wireless-control
base
(Figure
5).
1
2
1. Wireless-control base
3. Plug the wireless-control-base lead into the harness
adapter that was previously disconnected from the
wireless control base
g018879
Figure 5
2. Wire harness
(Figure 6
and
Figure
7).
1
1. Harness-adapter
lead to the wireless
control-base-harness lead
2. Harness-adapter
lead to the
wired-controller-harness
lead
1. Wire-harness adapter
2. Connect this wire-harness
lead to the wire-harness
adapter
3. Wireless control-base-wire
harness
4. Wireless-control base
4. Plug the harness-adapter lead into the
wired-controller-harness lead
Figure
7).
5. Plug the yellow wire from wired controller harness into
the pink wire located by the hour meter
Figure
7).
6. Connect the positive battery cable first and then
connect the negative battery cable.
4
2
g018908
Figure 6
3. Harness-adapter
lead to the
wired-controller-harness
lead
Figure 7
5. Pink wire located by the
hour meter
6. Wired controller
7. Yellow wire from the
wired-controller harness
(Figure 6
and
(Figure 6
3