Table of Contents

Advertisement

Load Sensor

Rig Load Display
from zero to 49.9 kiloNe-
wton (4.99t). Different
scales are available upon
request.
must be connected
between the sensor and
the cockpit display. The in-
terface can be calibrated for any particular
sensor.
The display unit to which the Load Sensor
is connected, has to be configured with sen-
sor number SE=14.
At all display units, where the Rig Load
Reading shall be enabled, function number
dF=28 must be activated.
Rig Load is displayed
Sensors from vari-
ous suppliers can be
connected (Navtec,
B&G).
Installation:
A Tecnautic Load
Sensor Interface
Sensor Cable:
6 pin plug RJ-11 (4 pins installed)
6 pin plug, 4-wire cable:
pin
round
flat-oval
#
cable
cable
1
-----
-----
2
white
white
3
brown
blue
4
yellow
cyan
5
green
magenta reserved
6
-----
-----
pin 1 and 6 must remain
unconnected
Pin #1
white lead onto pin
#2
Important in case of third party
sensor electronics:
All sensors (including their associated elec-
tronics) must only be wired to the display unit
via its sensor cable. No other electric connec-
tion between sensor and boat must exist. That
means only the supply from the display (GND
and +5 Volts) may be used. The current drawn
should not exceed 25 mA and should be
steady (+/- 1mA).
5
unused
+5 Volts
GND
Sensor signal
unused