5.3.5

Displaying total deceleration

i
The total deceleration is the end result of the brake test.
Step
Display total deceleration:
R
Service brake.
R
Parking brake.
5.3.6

Display switching

Step
Switching of display for braking
forces:
R
Measured values in bar chart form.
R
Measured values as a function of
time (curve trace).
5.3.7

Print-out of measurement results

i
Print-out is only possible if a printer set is available (special accessory).
Only stored values can be printed out.w
Step
1. Make sure the printer is switched
on.
2. Start print task.
Robert Bosch GmbH
Manual mode (normal operation) | BSA 43xx | 59
Remote control unit
+
+
Remote control buttons
Print button 2
Remote control buttons
Print button 1
Result / Analog display
"
The calculated total brake decelera-
tion is displayed.
Result / Display
 Display is switched.
Result / Display
 Printer is switched on
 "PrintManager" dialog box is
opened.
"
Measurement results are printed
out.