Bosch BSA 43 Series Original Instructions Manual page 62

Test lane with pc for passenger vehicles
Hide thumbs Also See for BSA 43 Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 39
en
62 | BSA 43xx | Automatic mode
Step
5. Measure braking forces:
R
Slowly and steadily depress brake pedal until
maximum braking force (slip) is attained.
R
Release brake pedal again.
i
Shut-off criteria:
$
Wheel lock-up (slip monitoring).
$
Vehicle out of position (slip rollers no longer
pressed).
$
Maximum braking force (slip) not attained on
braking and braking action remains at rolling
resistance level for more than six seconds.
6. Wait until set of rollers starts up again automatically.
Then drive vehicle off set of rollers.
|
1 691 606 210
2015-07-29
Result / Display
 The current values are displayed on the screen:
$
Braking force (F)
$
Pedal force (PD)
$
Braking force difference (∆F)
$
Deceleration (Z)
 Peak value display (approx. 5 seconds).
"
Braking force measurement is over.
Robert Bosch GmbH

Advertisement

Table of Contents
loading

Table of Contents