APPENDIX D- SECURING THE SONICWALL
Mounting the SonicWALL GX250 and SonicWALL GX650
The SonicWALL GX250 and SonicWALL GX650 are designed to be mounted in a
standard 19-inch rack mount cabinet. The following conditions are required for proper
installation:
•
Use the mounting hardware recommended by the rack manufacturer and ensure
that the rack is adequate for the application.
•
Four mounting screws, compatible with the rack design, must be used and hand
tightened to ensure secure installation. Choose a mounting location where all four
mounting holes line up with those of the mounting bars of the 19-inch rack mount
cabinet.
•
Mount in a location away from direct sunlight and sources of heat. A maximum am-
bient temperature of 104º F (40º C) is recommended.
•
Route cables away from power lines, fluorescent lighting fixtures, and sources of
noise such as radios, transmitters, and broadband amplifiers
•
Ensure that no water or excessive moisture can enter the unit.
•
Allow unrestricted airflow around the unit and through the vents on the side of the
unit. A minimum of 1 inch (25.44mm) clearance is recommended.