Guide To Programming Options; Programming The Control Panel With The D5200 Programmer; Table 4: Programming Error Displays - Bosch D9412GV2 Program Entry Manual

Table of Contents

Advertisement

D9412GV2/D7412GV2 | Program Entry Guide | 1.0
1.3

Guide to Programming Options

This guide is set up in a specific order. Related
program entries are grouped together in modules as
they appear in the specific product handlers. The
handler and the programming module are listed at the
top of each page to help you find specific programming
prompts.
This guide shows the programming options for each
product handler. Each option is listed with:
The Program Item Prompt: Each prompt is
shown as it appears in the D5200 Programmer
[refer to the D5200 Programmer Operations
Manual.(P/N: 74-06176-000)] or the Remote
Programming Software (RPS). Refer to the RPS
Operations Manual (P/N: 38849). For space
considerations, some prompts must be abbreviated
in the Programmer display. In these cases, the
meaning of the prompt is explained below the
prompt
Program Entry Default Setting: Because defaults
are set for the typical installation, programming
each prompt might not be necessary. Review the
default entries in the program record sheet shipped
with the control panel to determine which prompts
must be programmed.
Program Entry Selections: Only the selections
listed can be used for a particular program item.
Program Entry Description: Describes the
various entry selections. Read the descriptions
carefully to avoid improperly programmed
equipment.
Custom Programming: Select custom
programming (Yes or No) to expand programming
modules within the D5200. Programming Custom
as Yes allows parameters for special applications to
be visible in the programmer.
Bosch Security Systems | 5/05 | F001U003636B
Introduction
1.4
Programming the Control Panel with
the D5200 Programmer
Caution: Do not connect the D5200 to
the PROG connector without closing the
reset switch. Doing so causes SDI ##
TROUBLE and CALL FOR SERVICE to
display on the keypads. Door controllers
also activate, depending upon the SDI
failure DIP switch setting.
To connect the D5200 Programmer to the control
panel:
1. Close the reset switch, located in the upper
right corner of the control panel and labeled
S1 Reset, to place the D9412GV2 or
D7412GV2 Control Panel in the standby
mode.
2. Connect the Molex® connector at one end of
the cord to the connector labeled PROG on
the PCB and PROG CONN on the faceplate.
To retrieve the current control panel configuration,
press the [RECV (COPY)] key on the D5200 at the
NEWRECORD prompt. Refer to the D5200
Programmer Operation Manual (P/N: 74-06176-000)
for detailed information.
To write new configuration information for the
control panel, press the [SEND (LOAD)] key at the
NEWRECORD prompt. Refer to the D5200
Programmer Operation Manual (P/N: 74-06176-000)
for detailed information.
To disconnect the D5200:
1. Disconnect the the Molex® connector.
2. Open the reset switch.
When the reset switch is opened, the
control panel reboots and resumes normal
operation within 5 to 25 sec.

Table 4: Programming Error Displays

Display
INCOMPATIBLE
PANEL
CHECK
CORD/RESET PIN
EN | 7
Description
You are connected to the
wrong control panel or using
the wrong handler. Check the
faceplate for the model number
and the handler title.
Check the cord and the reset
pin