Condensate Composition; Regulations; Compliance With Standards And Regulations; Operating Limits Of The Boiler - Bosch Greenstar Series Installation And Service Instructions For Contractors

Residential gas condensing boiler
Table of Contents

Advertisement

Input/Output at elevation 0 - 2000 feet (0 - 610 m)
Sound pressure level
Max. supply temperature
Max. permissible operating pressure (P
Permissible ambient temperature
Nominal water capacity (heating)
Weight (without packaging)
Dimensions, W x H x D
Table 7 Technical data ZWB42-3A...
3.13

Condensate composition

The condensate volume and ingredients may change with regionally and
seasonally varying gas quality and air quality. Typically the following
ingredients and concentrations can be expected:
Substance
Ammonium
Lead
Cadmium
Chrome
Halogenated hydrocarbons
Hydrocarbons
Copper
Nickel
Mercury
Sulfate
Zinc
Tin
Vanadium
pH-value
Table 8 Typical condensate composition
Greenstar – 6721822579 (2021/01)
) heating
MS
Value in ppm (mg/l)
1.2
≤ 0.01
≤ 0.001
≤ 0.005
≤ 0.002
0.015
0.028
≤ 0.1
≤ 0.0001
1
≤ 0.015
≤ 0.01
≤ 0.001
4.8
Unit
dB(A)
°F ( °C)
psi (bar)
30 (2.07)
°F ( °C)
32 - 122 (0 - 50)
gal (l)
0.925 (3.5)
lbs. (kg)
110.2 (50)
inch
17-21/64" × 33-15/32"13-57/64"
(mm)
4

Regulations

Observe all rules, regulations, standards and guidelines applicable to the
installation and operation of this appliance in your country.
Valves external to the boiler must be fitted with T-handles and
condensate piping must be installed in accordance with the State
Plumbing Code.
4.1

Compliance with standards and regulations

The installation must conform to the requirements of the authority
having jurisdiction or, in the absence of such requirements, to the latest
edition of the National Fuel Gas Code, ANSI Z223.1./NFPA 54. In
Canada, installation must be in accordance with the requirements of
CAN/CSA B149.1, Natural Gas and Propane Installation Code.
This wall-mounted condensing gas boiler complies in its design and
mode of operation with the American National Standard ANSI Z21.13/
CSA4.9, latest edition for Gas-Fired Low-Pressure Steam and Hot Water
Boilers.
Other confirmed approvals and certifications are indicated by labels on
the boiler.
If so advised by the responsible agency, the installation must satisfy the
requirements of the standard for Controls and Safety Devices for.
Automatically Fired Boilers, ANSI/ASME CSD-1.
Install CO detectors per local regulations. Wall-mounted gas condensing
boilers require yearly maintenance ( Chapter 15, page 65).
4.2

Operating limits of the boiler

The heat exchanger has been designed and certified in accordance with
the ASME Boiler and Pressure Vessel Code, Section IV.
Maximum boiler temperature
Maximum operating pressure
Table 9 Operating limits
The hot water distribution system must comply with all applicable codes
and regulations. When replacing an existing boiler, it is important to
check the condition of the entire hot water distribution system to ensure
safe operation.
Common practice calls for inspecting an existing system in its entirety
and bringing it up to code. All pipework should be properly cleaned and
flushed.
Regulations
ZWB 42-3 A...
NG
LPG (propane)
≤ 45
≤ 45
187 (86)
187 (86)
30 (2.07)
32 - 122 (0 - 50)
0.925 (3.5)
110.2 (50)
(440 × 850 × 353)
187 °F (86 °C)
30 psi (2.07 bar)
23