Noises During Drying Cycle; Service; Door Seal Replacement; Figure 040-3: Seal Install Guide - Miele G 1 Series Technical Information

Hide thumbs Also See for G 1 Series:
Table of Contents

Advertisement

Technical Information
3.2

Noises during Drying Cycle

Symptom:
After the fan is switched on, there may be noises during the drying cycle.
Cause:
Fan impeller not firmly mounted.
Remedy:
Replace the fan (see Section 040-4.5).
4

Service

4.1

Door Seal Replacement

1. Open the door.
2. Remove the old seal.
3. Clean the groove around the cabinet.
Note:
Coating the seal with water may simplify installation.
4. Press the new seal in the groove; see Figure 040-3, Item 1. The seal lip
should point inwards.
5. Then press the middle of the new seal into the groove under the locking
plate; see Figure 040-3, Item 2. At the same time, press the seal into the
corners.
6. Now press the remaining seal parts into the groove, working upwards in
the direction of the arrows; see Figure 040-3, Item 3.

Figure 040-3: Seal Install Guide

72
G 1xxx/G 2xxx

Advertisement

Table of Contents
loading

Table of Contents