External Device Settings
To define the External Device communication settings, use the External Device keypad's STOP/RESET, ESC,
Up, Down, and SET keys.
Refer to your External Device manual for details.
1
Turn ON the External Device.
2
Press STOP/RESET to stop operations.
3
Press ESC to move to the Function Group.
4
Press ESC to select [C001].
5
Press Up or Down to select the function code.
6
Press SET.
7
Press Up or Down to select the value.
8
Press SET.
9
Restart the External Device.
Setting Value
Function Code
C071
C072
C074
C075
C096
GP-Pro EX Device/PLC Connection Manual
Setting Value
06
Communication speed (19200bps)
1
Modbus address (Modbus slave address)
00
Communication parity (Non-Parity)
1
Communication stop bit (1 bit)
00
Communication selection (Modbus-RTU)
18
Inverter MODBUS RTU Driver
Setup Description