Fujitsu 467 Manual page 23

Gdc board
Table of Contents

Advertisement

Prepared
Manfred Ortmann
Approved
120 Ohm termination is configurable per line via switches on board:
Following table shows the assignment of pins, signals and function from the CAN connector
X700:
Table 2-6: Pin assignment X800
Checked
SW700: 120 Ohm Termination for CAN 0
SW701: 120 Ohm Termination for CAN 1
Pin
Signal
1
VCC33
2
EXT_CAN0L
3
GND
4
EXT_CAN1L
5
GND
6
GND
7
EXT_CAN0H
8
EXT_CAN1H
9
VCC50
Preliminary
Document Number
Date
Revision
2008-05-14
PA 3.5
Function
3,3V switchable via R702
CAN 0 Low
Ground
CAN 1 Low
Ground
Ground
CAN 0 High
CAN 1 High
5V swichable via R701