HP Jet Fusion 4200 Product Documentation Site Preparation Manual page 9

Table of Contents

Advertisement

Fitting type: Metallic triclamp
Standard to meet: ISO 2852 or DIN 32676 or BS 4825 (ASME BPE)
Fitting diameter: 38 mm (1.5 in)
Piping requirement (only if using the processing station as a material filling method for the material loading
tank)
Flexible hoses should be suitable to transport combustible dust. Follow manufacturer's instructions
to earth the hoses to protect them from electrostatic charging.
Internal diameter of piping: approximately 36 mm.
Maximum length of pipe routing: 10 m.
Keep the number of bends along the route to a minimum. Use as large a bending radius as possible.
Hoses should be free from torsion in their routing and connection in order to avoid damage.
Use metallic, rigid pipes where possible; and they should be properly grounded. Use piping with low
roughness on its the internal surface.
Joints between pipe sections must be constructed correctly so that material does not build up around
the joints; you should ensure a good seal.
Bulk discharging system
You are recommended to use an explosion-protected bulk-discharging system to operate with
combustible dusts, compliant with the following normative specifications:
Operating with a bulk discharging system can cause dust clouds. Keep an area of at least 2 m around
the bulk discharging system clear of electric/electronic devices or any source of ignition.
An earth connection for the conveying pipes must be included in the bulk discharging system. Follow
the recommendation of the bulk discharging system manufacturer.
Maximum material flow rate supplied by the system should be 5 kg/min.
Static earthing clamps
You are required to use static earthing clamps when using material loading tanks
Return the site preparation checklist
The company owner or EHS manager must complete and return the checklist to your reseller or service
representative a minimum of two weeks before the day of installation.
NOTE:
Any delays during installation that are caused by an unprepared site will be charged to the customer.
Take care that your site is properly prepared to ensure a smooth and easy installation.
Recycle the supplies
HP provides many free and convenient ways to recycle your used HP cartridges and other supplies; see
http://www.hp.com/recycle/.
ENWW
Europe/IEC: Zone 22 or better, 200°C (392°F) or less
US/NEC: Class II, division 2, 200°C (392°F) or less
Customer responsibility