thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
refer to
Wear eye
instructions
Protection
1. safety
Warning! ensure that Health and safety, local authority and general workshop practice regulations are
strictly adhered to.
do not use the unit if it, or any attachment, is damaged.
8
maintain tester in good and clean condition for best and safest performance.
9
if required, ensure that the vehicle to be worked on is adequately supported with axle stands or ramps and is chocked.
9
Put transmission in PArK (for automatic transmission) or neutrAl (for manual transmission) and make sure the parking brake is
9
engaged, or wheel chocks are in place.
Wear approved eye protection. A full range of personal safety equipment is available from your sealey dealer.
9
Wear suitable clothing to avoid snagging. do not wear jewellery and tie back long hair.
9
Warning! use extreme caution when working around the ignition coil, distributor cap, ignition wires and spark plugs. these
components create hazardous voltages when the engine is running.
do not connect or disconnect any test equipment with ignition on or engine running.
8
Keep a fire extinguisher nearby, which is suitable for gasoline/chemical/electrical fires.
9
Account for all tools and parts being used and do not leave any in the engine bay.
9
Keep reset tool dry, clean and free from oil, water and grease. use a mild detergent on a clean cloth to clean the outside of the tool.
9
operate the vehicle in a well-ventilated work area; exhaust gases are poisonous.
9
iMportant: Always refer to the vehicle manufacturer's service instructions to establish the current procedure and data.
these instructions are provided as a guide only.
Warning! the warnings and instructions discussed in this manual cannot cover all possible conditions and situations that may occur.
it must be understood that common sense and caution are factors which cannot be built into this product, but must be applied by the
operator.
2. introduction
essential tool for extinguishing the service indicator and resetting electronic
Parking Brake on land rover and range rover vehicles. simple push button
operation allows ePB cable to be released and re-attached and, in the event
that the emergency hand brake has been activated, allows the user to reset
the system, and clears codes that may have been generated as a result of the
emergency cable being pulled. it also allows the ePB to be un-jammed when
the vehicle has entered a state of brake screech when applying the parking
brake, where the rear brakes squeak or rub when the vehicle is moving or
there is evidence of shoe-drag. Powered by connection to the vehicle.
3. operation
3.1.
the Vs8624 tool:
is compatible with the latest CAN vehicles.
enables Service and Inspection mode for safe working practices.
is updateable.
3.2.
The VS8624 Land Rover/ Range Rover Service Indicator
reset and electronic Park Brake (ePB) tool has been designed to
extinguish service indicators and to mount the cable for the ePB for
land rovers and range rovers. in addition, it will also allow the resetting of
the ePB system if the emergency release cable has been activated, and to
release the ePB in the event that it has become jammed.
3.3.
service function:
service reset – Will reset the service indicator on the vehicle.
© Jack sealey limited
instructions for
service indicator & epb reset tool -
land rover / range rover
model no:
electrical
Wear Protective
shock
clothing
Hazard
24,000km / 15,000 miles / 12 months
12,000km / 7,500 miles / 6 months
Original Language Version
vs8624
VS8624 | Issue 2 01/07/16

Advertisement

loading

Summary of Contents for Sealey VS8624

  • Page 1 Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Press the ‘oK’ button to reset the service indicator. the function led’s will flash to indicate a successful reset. 3.6.4. if the reset is unsuccessful, mode led selection will flash. Original Language Version © Jack sealey limited VS8624 | Issue 2 01/07/16...
  • Page 3 As part of this process, the clear codes routine is automatically run to clear any codes within the ePB system. Note: For safety reasons we recommend removing the EPB 30A fuse from the battery junction box. Original Language Version © Jack sealey limited VS8624 | Issue 2 01/07/16...
  • Page 4 Mode LED Selection will flash. note: Any codes that are not able to be cleared will remain on the module. use the sealey Vst electronic Auto service and diagnostic tool to determine what these codes are and what steps need to be taken to resolve the problem.
  • Page 5 Original Language Version © Jack sealey limited VS8624 | Issue 2 01/07/16...
  • Page 6 TECHNICAL HELP LINE No. 01284 757505 Please register your product with sealey by completing the registration form on-line at www.sealey.co.uk navigate to register Product. By registering your product you can take advantage of sealey product and technical updates via email. environmental protection recycle unwanted materials instead of disposing of them as waste.