ABB H81381P Series Product Manual

ABB H81381P Series Product Manual

Ip pushbutton outdoor station

Advertisement

Quick Links

2TMD041800D0010 │ 07.12.2020
Product manual
ABB-Welcome IP
H81381P.-. IP pushbutton outdoor station

Advertisement

Table of Contents
loading

Summary of Contents for ABB H81381P Series

  • Page 1 2TMD041800D0010 │ 07.12.2020 Product manual ABB-Welcome IP H81381P.-. IP pushbutton outdoor station...
  • Page 2: Table Of Contents

    Inha ltsv erzeichnis Notes on the instruction manual ......................4 Safety ..............................4 Intended use ............................5 Environment ............................6 ABB devices ..........................6 Product description ..........................7 Device type ..........................7 Control elements........................8 Terminal description ........................9 Lock type and connection ......................10 Technical data ............................
  • Page 3 Inhaltsverzeichnis │3 Product manual 2TMD041800D0010...
  • Page 4: Notes On The Instruction Manual

    Please keep this manual in a safe place. If you pass the device on, also pass on this manual along with it. ABB accepts no liability for any failure to observe the instructions in this manual. Safety...
  • Page 5: Intended Use

    Intended use Intended use As part of the ABB-Welcome IP system, this device can only be used with accessories from that system. Security mode This outdoor station runs in "Security mode" by default to guarantee high security. In "Security mode", this outdoor station requires a certificate issued by the management software before it can function normally.
  • Page 6: Environment

    ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company.
  • Page 7: Product Description

    Product description Product description Device type Size (HxWxD) Article Product ID Product name Colour number Unit: mm H81381P1-S 2TMA130010X0001 OS, IPpush, 1 gang Stainless 135 x 277 x 29 steel H81381P2-S 2TMA130010X0002 OS, IPpush, 2 gang Stainless 135 x 277 x 29 steel Stainless H81381P3-S...
  • Page 8: Control Elements

    Product description Control elements Function Camera Speaker and microphone integration Round pushbutton End strip │8 Product manual 2TMD041800D0010...
  • Page 9: Terminal Description

    Product description Terminal description Function Reset button Micro USB update connector Plug-in clamps (DC+...GND) for standalone power supply Plug-in clamps (LOCK...GND) for door opener Plug-in clamps (COM...NC...NO) for floating output, door opener LAN (PoE) Connector for next module Connector for exit button Connector for the sensor used for door status detection Connector for 5"...
  • Page 10: Lock Type And Connection

    Product description Lock type and connection Lock type Operation type Voltage Wiring type Electrical strike ⎓ Power on to open Type A/B 12 V lock, 12V Electrical strike ⎓ Power on to open Type B 24 V lock, 24V Electrical rim ⎓...
  • Page 11: Technical Data

    Technical data Technical data Designation Value Rating voltage 24 V DC Operating voltage range 20-27 V DC 27 V DC, 300 mA Rating current 24 V DC, 330 mA Operating temperature -40 °C…+55 °C Product dimensions 135mm x 276.9 mm × 17.6 mm Camera type CMOS Camera viewing angle...
  • Page 12: Mounting/Installation

    Mounting/Installation Mounting/Installation Warning Electric voltage! Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. – Disconnect the mains power supply prior to installation and/or disassembly! –...
  • Page 13: Mounting

    Mounting/Installation Mounting 7.2.1 Preparation Use gloves to protect yourself against cuts. 7.2.2 Installation height 1.5 m 5 feet │13 Product manual 2TMD041800D0010...
  • Page 14 Mounting/Installation Note The following installation situations must be avoided without fail to ensure picture quality: ■ Direct light ■ Direct sunlight ■ Extremely bright picture background ■ Highly reflective walls on the opposite side of the door station ■ Lamps or direct light sources │14 Product manual 2TMD041800D0010...
  • Page 15: Surface-Mounted Installation

    Mounting/Installation 7.2.3 Surface-mounted installation 32 mm 40 mm 71 mm │15 Product manual 2TMD041800D0010...
  • Page 16: Flush-Mounted Installation

    Mounting/Installation 7.2.4 Flush-mounted installation 1. Flush-mounted without pre-installation box 117 mm 46 mm 1X 3 │16 Product manual 2TMD041800D0010...
  • Page 17 Mounting/Installation 2. Flush-mounted with pre-installation box 126 m m 68 m m │17 Product manual 2TMD041800D0010...
  • Page 18: Cavity Wall Installation

    Mounting/Installation 7.2.5 Cavity wall installation │18 Product manual 2TMD041800D0010...
  • Page 19: Dismantling

    Mounting/Installation 7.2.6 Dismantling 7.2.7 Replacing the nameplate │19 Product manual 2TMD041800D0010...
  • Page 20: Commissioning

    Commissioning Commissioning The outdoor station must be configured via the indoor station. Step1: Outdoor station enters engineering mode Power on the outdoor station, wait a while until all 3 LED indicators go out. ■ ■ Hold the first button on the outdoor station for 10 s until all 3 LED indicators start to flash. The outdoor station will quit engineering mode after 5 minutes.
  • Page 21 Commissioning On the "System settings" screen, click "Engineering settings", enter the engineering password (default is 345678) to enter the settings page. Step3: Indoor station configures outdoor station On the "Engineering settings" screen, click "Outdoor station settings" to configure the outdoor station.
  • Page 22: Operation

    Operation Operation Call a resident Press the button to start a call (default) and press again to restart the call. │22 Product manual 2TMD041800D0010...
  • Page 23: Call A Guard Unit

    Operation Call a guard unit If the outdoor station has been configured via the indoor station, we can press the pushbutton to call the designated guard unit. Please refer to the product manual for the IP touch 7". │23 Product manual 2TMD041800D0010...
  • Page 24: Turn On A Light

    Operation Turn on a light If the outdoor station is configured by the indoor station, we can press the pushbutton to switch on the light connected to the IP actuator. Please refer to the product manual for the IP touch. │24 Product manual 2TMD041800D0010...
  • Page 25: Cyber Security

    H81381P.-. product, the network, its system and interfaces against any kind of security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB and its affiliates are not liable for damages and/or losses related to such security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information.
  • Page 26: Deployment Guideline

    Malware prevention solution The H81381P.-. device is not susceptible to malware, because custom code cannot be executed on the system. The only way to update the software is by firmware upgrades. Only firmware signed by ABB can be accepted. 10.7 Password rule The user must change the engineering password when accessing the engineering settings for the first time.
  • Page 27: Notice

    We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.
  • Page 28 Contact us Notice We reserve the right to at all times make technical changes as well as ABB Xiamen Smart Technology Co., Ltd. changes to the contents of this No.7, Fangshan South Road, Hi-tech area, Torch document without prior notice.

This manual is also suitable for:

H81381p1-sH81381p2-sH81381p3-s

Table of Contents