Terminating "Id 40" Network Connection; Troubleshooting Ppp Connection To Id 40/Slk - Bosch Rexroth ID 40 Manual

Table of Contents

Advertisement

10.3.4

Terminating "ID 40" network connection

If desired, you can terminate the connection by selecting Connect To from the Start
menu and opening the connection dialog box, then clicking on Disconnect in the
ID 40 connection.
The connection can be re-established at any time.
Terminate the network connection before removing the ID 40 diagnostics cable.
10.3.5

Troubleshooting PPP connection to ID 40/SLK

10.3.5.1 Error message appears when establishing connection
Possible causes of failed connection attempt:
• The ID 40/SLK is not connected - or connected to a COM port without a
communication cable
• The assigned COM port is already being used by another program or connection
• The baud rate is not configured properly
• Hardware flow control is active
10.3.5.2 Behavior during fatal system errors
In exceptional instances, the SLK can experience a fatal system error. This
is indicated by all display segments flashing and all functions ceasing, see
Chapter 12.1.2 "Fatal system errors".
In addition, the SLK serial interface switches from PPP mode to emergency shell
mode.
In this instance, access through a web browser is no longer possible. If this occurs,
terminate the network connection (see Chapter 10.3.4 "Terminating 'ID 40' network
connection") and start the ID 40/KONF program to diagnose the fatal system error;
see Chapter 12.1.2 "Fatal system errors" on how to proceed.
Web interface 129/176
3 842 530 344/2014-05, MIT: ID 40, Bosch Rexroth AG
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents