CMD
Command
Description
code
7
Set parameters
The indicated data area is added to the
for pretransmit
pretransmit.
This command can be selected multiple
times, whereby the various areas can
overlap.
8
Configure
Begin or finish setting pretransmit param-
pretransmit
eters.
Start "single transmit" (ST) or "multiple
transmit" (MT).
Delete all parameterized data areas. Stop
pretransmit
Query
Data0–Data3:
SLK address
Data4–Data5:
No. bytes,
Data4 always 0
Data6.n:
Data in pretransmit to be
written
Data0:
0: Begin setting parameters
1: Finish setting parameters
2: Start ST
3: Start MT
4: Delete parameters
5: Stop pretransmit
3 842 530 344/2014-05, MIT: ID 40, Bosch Rexroth AG
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy
Profibus DP
53/176
Reply
Data0:
Result
Data0:
Result