DIAGNOSTIC: Displaying Inlet Air Flow
Used to display the airflow value at the inlet
of the heater box being measured by the ma-
chine control.
After all saved fault codes have been dis-
played, press the Wrinkle Guard button to
activate airflow detection. A 30 or 50 second
countdown timer will start and the dryer will
turn on.
If the dryer is cold, the countdown will start
at 50 seconds.
NOTE: If the dryer is extremely cold (less
than 40°F [4.4°C] ) the airflow may not
be detected properly, and "--" will be dis-
played.
If the dryer is hot, the countdown timer will
start at 30 seconds (cool down period) fol-
lowed by an additional 50 second count-
down.
A Dryness Level modifier LED will also be il-
luminated to indicate the airflow range corre-
sponding to the number displayed.
The More LED will be illuminated for air-
flow readings above 40 cfm.
The Normal LED will be illuminated for air-
flow readings between 29 and 40 cfm.
The Less LED will be illuminated for airflow
readings less than 29 cfm.
If airflow value is low, check to make
sure the lint screen is clean, the door
seal is in place and the vent is not ob-
structed.
DIAGNOSTIC: Displaying Line Voltage
Used to display the line voltage currently be-
ing measured by the machine control:
After all saved fault codes have been dis-
played, press the Cycle Signal button. The
last 2 digits of the voltage value will be dis-
played on the dual 7-segment display.
A Dryness Level modifier LED will also be il-
luminated to indicate the voltage range cor-
responding to the number displayed. The
Dryness Level LEDs relate to specific voltage
ranges as follows:
The More LED will be illuminated for high
voltage readings (above 260 VAC).
The Normal LED will be illuminated for nor-
mal voltage readings (200-260 VAC).
The Less LED will be illuminated for low
voltage readings (below 200 VAC).
If the line voltage is not seen on L2 the
display will flash L2. Go to TEST #1.
DEACTIVATING THE DIAGNOSTIC
TEST MODE
Press the Stop button twice to exit diagnos-
tics.

ACTIVATING THE MANUAL LOAD TEST

1.
Be sure the dryer is in standby mode
(plugged in with all indicators off, or with
only the Clothes Dry indicator on).
2.
Select any one button (except Stop) and
follow the steps below, using the same
button (remember the button):
Press/
Release
Press/
hold 2-5
for 2-5
hold 2-5
seconds
seconds
seconds
Now press any key (except Stop) and the
control will advance through each step of the
following sequence:
SINGLE ELEMENT MODELS:
1. Turn on motor.
2. Motor + Heater.
3. No loads on.
4. Start sequence again at 1.
DUAL ELEMENT MODELS:
1. Turn on motor.
2. Motor + Heater 1.
3. Motor + Heater 2.
4. Motor + Heater 1 + Heater 2 + Drum Light.
5. No loads on.
6. Start sequence again at 1.
DEACTIVATING THE
MANUAL LOAD TEST
Press the Stop button to exit this mode.
6-4
Release
Press/
Release
for 2-5
hold 2-5
for 2-5
seconds
seconds
seconds
Flash "Heavy Duty" LED.
Flash "Casual" LED.
Flash "Normal" LED.
Flash "Heavy Duty" LED.
Flash "Casual" LED.
Flash "Timed Dry" LED.
"Drum Light" LED.
Flash "Normal" LED.
Press/
hold 2-5
seconds