Gas Requirements
• Use propane, butane or their mixture only. See rating label on the appliance.
• The appliance requires approved gas hose in <150 cm length and a gas regulator.
The hose and regulator assembly must conform to local standard codes.
• Regulator maximum inlet pressure must not exceed 690 kPa.
• Gas connection .635 cm LH is to be used with 1.5Bar regulator. Gas connection
.9525 cm LH is to be used with 0-2 bar regulator(when in need).
• This appliance is designed for gas cylinders up to 15 kg.
• A dented, rusted or damaged gas cylinder may be hazardous and should be
checked by an authorized dedicated gas specialist. Never use a gas cylinder with
a damaged valve connection.
• Never connect an unregulated gas cylinder to the heater.
• Never twist the flexible tubes and hoses. Torsional stress on tubes and hoses
might lead to gas leakage over time.
• The installation of the gas cylinder must conform to local codes, or in the absence
of local codes, to the standard for the storage and handling of liquid petroleum
gases.
• Disconnect the gas cylinder when the heater is not use.
• Isolate the appliance from the cylinder by means of the cylinder isolating valve
when not in operation.
Leak Testing
Gas connections on the heater are leak tested at the factory prior to shipment. A
complete gas tightness check must be performed at the installation site due to
possible mishandling in shipment and/or installation or because of excessive pressure
being applied to the heater. The heater must be checked with a full cylinder.
1. Make sure the safety control valve is in the OFF position.
2. Make a soapy water solution of one part liquid detergent and one part water. The
soapy water solution can be applied with a spray bottle, brush or rag to all gas
connections.
WARNING: Never leak test while smoking! In the event of gas leakage, the
appliance must not be used or if still lit, the gas supply must be shut off and the
leakage repaired before it can be used again.
3. Turn the gas supply ON. And check all the connections with the soapy water
solution. Soap bubbles will appear in case of a Ieak.
4. In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the
gas supply ON and recheck. Contact your dealer or gas supplier for assistance if
bubbles continue to appear.

Lighting/Operating Instructions

Preparation for Operation
1. Remove the heater from the box and check for possible shipping damage. If any is
found, immediately notify the factory.
2. Open the handle and screw plastic bag.
3. Secure the handle to the heater with the
four screws provided through the four holes
at the top of the unit. See Figure 2.
NOTE: A gas hose and gas regulator are
NOT included with the heater.
4. Connect the gas supply hose to the
pressure regulator and connect the
regulator to a suitable gas cylinder.
5. Connect the hose to the gas connector
on the heater by rotating the hose fitting
clockwise.
6. Open the cylinder's gas valve and check all gas connections with a soap and
water solution as described above.
7. Connect power cord to well-grounded 220V~240V, 50Hz source of power.
DXHP060E
Igniter
Gas Valve
Button
Power
Gas Connector
Switch
6
Figure 2
DXHP125E
Igniter
Control Knob
Gas Valve
Power
Button
Switch
Gas Connector