Download Print this page

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY
 WARNING! It is the responsibility of the owner and the operator to
read, understand and comply with the following: You must check all
electrical products, before use, to ensure that they are safe. You
must inspect power cables, plugs, sockets and any other connectors
for wear or damage. You must ensure that the risk of electric shock
is minimised by the installation of appropriate safety devices. A
Residual Current Circuit Breaker (RCCB) should be incorporated in
the main distribution board. We also recommend that a Residual
Current Device (RCD) is used. It is particularly important to use an
RCD with portable products that are plugged into a supply which is
not protected by an RCCB. If in any doubt consult a qualified
electrician. You may obtain a Residual Current Device by
contacting your Sealey dealer.
You must also read and understand the following instructions
concerning electrical safety.
1.1.1. The Electricity at Work Act 1989 requires that all portable
electrical appliances, if used on business premises, are tested
by a qualified electrician, using a Portable Appliance Tester
(PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of
electrical appliances responsible for the safe condition of
those appliances and the safety of the appliance operators. If
in any doubt about electrical safety, contact a qualified
electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance
is safe before connecting it to the power supply. See 1.1.1.
and 1.1.2. and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against
short circuit and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear
or damage and check all connections to ensure that
none is loose.
1.1.6. Important: Ensure that the voltage marked on the appliance
matches the power supply to be used and that the plug is
fitted with the correct fuse - see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors.
Immediately have any faulty item repaired or replaced by a
qualified electrician. When a BS 1363/A UK 3 pin plug is
damaged, cut the cable just above the plug and dispose of
the plug safely.
Fit a new plug according to the following instructions (UK only).
a)
Connect the GREEN/YELLOW earth wire to the
earth terminal 'E'.
b)
Connect the BROWN live wire to the live terminal 'L'.
c)
Connect the BLUE neutral wire to the neutral terminal 'N'.
d)
After wiring, check that there are no bare wires, that all
wires have been correctly connected, that the cable outer
insulation extends beyond the cable restraint and that the
restraint is tight.
Yellow & Green
Earth Wire
Blue
Neutral
Wire
FUSE RATING 13 AMP
© Jack Sealey Limited
1.1.10.Products which require more than 13 amps are supplied without
1.1.11. If an extension reel is used it should be fully unwound before
1.2.
1
2
Brown
3
Live
Wire
4
5
6
Cable
7
Restraint
8
9
10
Original Language Version
INSTRUCTIONS FOR:
WET & DRY VACUUM CLEANER
PC100
MODEL No:
Double insulated products, which are always marked with
this symbol
, are fitted with live (brown) and neutral
(blue) wires only. To rewire, connect the wires as indicated
above - DO NOT connect either wire to the earth terminal.
a plug. In this case you must contact a qualified electrician to
ensure that a suitably rated supply is available. We recommend
that you discuss the installation of an industrial round pin plug and
socket with your electrician.
connection. A reel with an RCD fitted is preferred since any
appliance plugged into it will be protected. The cable core
section is important and should be at least 1.5mm², but to be
absolutely sure that the capacity of the reel is suitable for this
product and for others which may be used in the other output
sockets, we recommend the use of 2.5mm² section cable.
GENERAL SAFETY
Disconnect the cleaner from the power supply before servicing,
changing accessories, or performing any maintenance.
Use only genuine parts and accessories. Unauthorised parts
and accessories may be dangerous and will invalidate
your warranty.
Maintain the cleaner in good condition. Use autho r i s e d
a g e n t for servicing. Keep machine clean, but DO NOT
use solvents.
For dry vacuuming ensure the cloth filter is firmly in place
before operating the cleaner.
DO NOT operate the unit without a filter in place. Using the
cleaner without a filter will result in motor failure and
will invalidate your warranty.
Wear protective clothing and gloves.
DO NOT allow children or untrained persons to operate the
cleaner.
DO NOT place attachments close to your face (especially
eyes, ears, etc). Do not point the hose end at other
persons or animals.
DANGER! DO NOT vacuum hot or glowing ash, cigarette
ends, inflammable, explosive, corrosive or other dangerous
substances.
DO NOT leave machine running unattended. Turn power supply
OFF, and DO NOT leave the vicinity until motor has come to a
complete stop.
DO NOT operate the cleaner while under the influence of
drugs, alcohol or impairing medication, or if you are tired.
DO NOT use the cleaner in the rain or in very damp conditions.
DO NOT use the cleaner for a task it is not designed to
perform.
When not in use, store the cleaner in a safe, dry, childproof
location.
2. SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PC100
Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000W
Supply:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V
Air Flow:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90m³/hr
Drum Size:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10ltr
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3kg
Vac Accessories Ø: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35mm
Filter Type:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cloth & Foam
Replacement Cloth Filter. . . . . . . . . . . . . . . . . . PC100.ACC4
Replacement Foam Filter . . . . . . . . . . . . . . . . . PC100.ACC2
PC100
Issue: 3(L) - 11/08/16

Advertisement

loading

Summary of Contents for Sealey PC100

  • Page 1 Yellow & Green Model No: ........PC100 Earth Wire Motor Power: .
  • Page 2 Connect the brush or crevice tool to the other end of the hose. 4.10 When vacuuming is complete the brush and crevice tools can be stored using the grooved stowage positions on either side of the power head. Original Language Version © Jack Sealey Limited PC100 Issue: 3(L) - 11/08/16...
  • Page 3 The unit will now blow through the hose and can be used to clear obstructions within the pipe. WARNING! If after a few seconds the hose is still blocked turn  of the unit and clear the hose manually. Original Language Version © Jack Sealey Limited PC100 Issue: 3(L) - 11/08/16...
  • Page 4 GUARANTEE WILL BE INVALIDATED. ALWAYS KEEP A SPARE FILTER HANDY. Replacement Cloth Filter ....... . PC100.ACC4 Replacement Foam Filter .