Diaphragm, Single Acting Cylinder - GE FVP110 Maintenance Manual

Table of Contents

Advertisement

GE Energy
Housing Materials:
Case: Aluminum die-cast
Paint: Polyurethane resin-baked finish
Color: Grey
Communication:
Digital: FOUNDATION fieldbus
Supply Voltage:
9 to 32V DC for general use and flameproof type
9 to 24V DC for intrinsically safe type Entity model
9 to 17.5V DC for intrinsically safe type FISCO model
Conditions of Communication Line:
Supply Voltage: 9 to 32V DC
Supply Current: 17 mA (max)
Output Signals and Pressure Gauge Scale:
No gauge is standard. Pressure gauge can be selected as option. The supply
pressure unit on the name plate for non-gauge model is Pa.
Calibration
Unit
kPa
2
kgf/cm
bar
psi
Table 5 Diaphragm, Single Acting Cylinder
Supply Air
Pressure
140 to 400
1.4 to 4
1.4 to 4
20 to 60
FVP 110 Fieldbus Valve Positioner Manual
Pressure Gauge Scale
Supply Air
400
4
4
60
74
Output Signal
400
4
4
60