-For combining indoor units with outdoor units, refer to the
outdoor unit's installation manual.
7.

Installing the Unit

7. Installing the unit
The air handler can be installed in a vertical, horizontal (Right and
Left) and Downflow configuration as shown below. The units are
designed for "0" zero clearance to combustibles. 24" is required for
The air handler can be installed in a vertical, horizontal (Right and Left) configuration as shown in step 10.1.
through 10.3. The units are designed for "0" zero clearance to combustibles. 24 in. (610 mm) is required for
service access to the front of the unit. (See below) Regardless of
service access to the front of the unit (see Installation Clearance). Regardless of mounting configuration,
mounting configuration, the air handler must be mounted level to
the air handler must be mounted level to facilitate proper condensate drainage.
facilitate proper condensate drainage.
Installation Clearance
Installation Clearances
TOP View
Vertical Installation
Clearance Area
24"
Width of Unit
PA79D202H01
Specifications are subject to change without notice.
SVZ-KP12,18, 24, 30, 36NA
TOP View
Horizontal Installation
Clearance Area
Length of Unit
17
9.A. Vertical Ins
supported on the b
plenum below or fie
Securely attach the
plenum.
The side return can
24 only. If the side
installer to ensure
the cabinet. Whe
provided dimples to
wiring.
24"