E1032
To replace the display you will need a new display including display frame, see
the
Available Spare Parts
Follow the steps below:
1. Power off the operator panel.
2. Follow the instructions under
3. Unlock the two flex cable connectors by pressing the connector flanges towards
the cable and disconnect the flex cables from the power card.
The connectors must be unlocked on both sides before removing the cables.
4. Gently press the power card towards the top of the panel as shown in the illustra-
tion above to release the power card from the power card holders.
Then tilt the bottom of the card away from you.
5. Disconnect the two flex cables and the plain cable on the back side of the power
card and then remove the power card.
6. Insert the two screwdrivers between the display frame and the aluminum casing
illustrated below. Press and bend gently on the display frame to unlock the frame
and tilt up the display frame.
7. Mount the new display unit.
8. Re-assemble the panel in reverse order.
Mitsubishi Electric, MA00758A
section.
Replacing the Rear Cover
power card