Network Submenu; Defaults Submenu - Bosch NDN-498V03-21P Installation And Operation Manual

Ndn-498 series flexidome2x ip camera
Hide thumbs Also See for NDN-498V03-21P:
Table of Contents

Advertisement

FlexiDome2X IP Camera
6.2.2

Network submenu

To operate the camera in your network, a network-valid IP
address must be assigned. The factory default IP address is
192.168.0.1
Function
Selection
IP Address
Subnet
Mask
Gateway
DHCP
Exit
The new IP address, subnet mask, and gateway address are set
when leaving the menu. The camera reboots internally and the
new values are set after a few seconds.
6.2.3

Defaults submenu

Item
Restore All?
Bosch Security Systems
Description
Enter an IP address for the camera. Use
LEFT/RIGHT to change position in the
address, use UP/DOWN to select the digit.
Use SELECT to exit the address edit
screen.
Enter the Subnet mask (default
255.255.255.0).
Enter a Gateway address.
If the network has a DHCP server for
dynamic IP address allocation, set this
parameter to On to activate the automatic
acceptance of DHCP-assigned IP
addresses.
Return to the Install menu.
Selection
No, Yes
Installation and Operation Manual
Description
Restores all settings of the six modes
to their default (factory) values. Select
YES then press the Menu/Select
button to restore all values.
When completed the message
RESTORED! is shown.
Camera set-up | en
AR18-10-B006 | v1.1 | 2010.06
41