NEC N8146-19 User Manual page 28

Dust proof bezel with sensor

Advertisement

3.Installing/Removing the Bezel to the Server
Take the steps below to install the bezel to the server.
●Read the sections "Safety Precautions" and "Handling precautions" in the User's Guide
of the server in which you are going to install the bezel to install or remove
the bezel safely and properly.
Note: The outer dimension of GT110d-S, NS100Tb is as follows after the bezel is installed.
93.0 mm (Width) × 411.5 mm (Depth) × 363.0 mm (Height) (With air duct, stabilizers, and projection excluded)
190.0 mm (Width) × 421.5 mm (Depth) × 386.5 mm (Height) (With air duct, stabilizers, and projection included)
1. Power off the server, and disconnect the power cord.
2. Pull the air duct at the top of the server
in the direction shown by an arrow in the figure,
and remove the air duct.
3. Lay down the server. Slide the side cover toward rear of the server (①in the figure)
while pushing the two eject buttons on the side cover, then remove the side cover.
4. Pull down the three release tabs (② in the figure) located at the upper side of front bezel,
and pull the front bezel toward front of the server until tabs are almost disengaged
from the chassis frame (③ in the figure).
Eject Button
● If the bezel is pulled too much, fixing hooks at the lower part of
the bezel may be damaged.
Slide the side cover in the
direction shown by an arrow.