15. Holding the FAN unit, fix the exhaust air filter B with the unit fixing screw removed in
the step 12.
If the screw does not fit the hole, confirm that the screw hole on the lower
fan unit aligns with the center of the hole on the exhaust air filter B.
16. Install the side cover by the reverse procedure of removing.
Hooks at the top of the server
本装置底面側
Hooks at the bottom of the server
のフック
Rear view of side cover
サイドカバーの裏側
● Make sure that hooks at both the top and bottom of the side cover
are securely inserted in the holes on the server frame.
And also, when the cover is being installed to the server, make sure that the
hook at the front side of the side cover is securely inserted in the server
frame. If not, the cover can not be installed to the server properly.
FAN Unit
Fix with the screw
本装置上面側
のフック
Plate for the
chassis lock
筐体ロ
プレー
34
Insertion holes for the hooks
The hooks at the front of the server
Insertion holes for the hooks
Frame of the server