Interfaces; Interfaces At The Vdp; Overview - Bosch Rexroth IndraControl VDP 16.3 Project Planning Manual

Operator display
Table of Contents

Advertisement

IndraControl VDP 16.3, VDP 40.3, VDP 60.3 Operator Display
7

Interfaces

7.1

Interfaces at the VDP

7.1.1

Overview

Fig. 7-1:
Interface to the control cabinet PC with CDI interface
Fig. 7-2:
Interface to the control cabinet PC with CDI+ interface
NOTICE
Use only shielded cables and metallic or conductive connector/coupling
covers with large-area shield support.
NOTICE
Ensure that the functional earth is connected, because otherwise the
electronics can be destroyed by a potential difference between the
VDP 16.3/40.3/60.3 and the PC if the voltage supply is interrupted to only
one device and established again. A direct connection between the functional
earth and the VDP xx.3 and the VPB 40.3 and VSB 40.3 is recommended. If
the functional earth is wired at a neutral point, also connect the control
cabinet PC (VPB 40.3, VSB 40.3) to this neutral point.
Name at
Availability Connection type
the
housing
X1S1
At all
24 V DC voltage supply Phönix
devices
XUSB1/2
At all
2 USB interfaces
devices
XUSB3/4
At all
2 USB interfaces
devices
S1
X1S1
XVID
XSER
XUSB1/2 XUSB3/4 XUSBIN
Off: Cable length ≤ 30 m
not
used
On: Cable length > 30 m
Malfunctions due to insufficient shielding!
Material damages to electronics due to
missing functional earth!
Connector
type, integrated
connector strip,
3-pin, MC1,5/3-
G-3,5 THT
USB socket,
4-pin, type A
USB socket,
4-pin, type A
R911323862_Edition 07 Bosch Rexroth AG
35/57
Interfaces
Mating
connector or
cable (from
outside)
Phönix socket
strip,
3-pin, FK-MCP
1,5/3-ST-3,5
USB plug,
4-pin, type A
USB plug,
4-pin, type A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents