Maintenance; Maintenance Plan; Lcd Display - Bosch Rexroth IndraControl VDP 16.3 Project Planning Manual

Operator display
Table of Contents

Advertisement

IndraControl VDP 16.3, VDP 40.3, VDP 60.3 Operator Display
8

Maintenance

8.1

Maintenance plan

8.2

LCD display

The operator terminals VDP 16.3/40.3/60.3 are maintenance-free. However,
some components are subject to wear and are to be replaced.
NOTICE
The degree of protection IP is to be guaranteed during maintenance!
NOTICE
If screws were removed because of maintenance works, fasten them again
with the corresponding tightening torque according to the following table.
Thread
M2,5
M3
M4
M5
Tab. 8-1:
Tightening torques
Include the following tasks into the maintenance schedule:
Clean the screen at least once a week using an antistatic fabric or a
cleansing agent containing alcohol.
NOTICE
Do not use any solvents (e. g. diluents)!
Do not use high pressure cleaning devices!
Check all plug and terminal connections of the components for proper
tightness and possible damage at least annually. Check that cables are
not broken or crushed. Replace damaged parts immediately.
Check the fan at least once a year, if existent.
CAUTION
Do not touch the fan impeller with your hands and ensure that it does not
come into contact with other objects.
A fading backlight causes a progressive deterioration of the readability of the
LCD display, so that a backlight replacement is necessary. For further
information, please contact the Bosch Rexroth Service.
Loss of IP degree of protection due to
incorrect maintenance.
Damage to the mechanics caused by wrong
tightening torque.
Mounting torque
0.4 Nm
0.7 Nm
1.4 Nm
2.8 Nm
The surface of the foil as well as the
display cover are dissolved by solvents!
Risk of injury by rotating fan impeller!
R911323862_Edition 07 Bosch Rexroth AG
41/57
Maintenance

Hide quick links:

Advertisement