Preventing Operation of
Cross-point Buttons
Preventing Operation of Cross-Point
Buttons (Inhibit Function)
For each cross-point button in the cross-point control
block, you can temporarily inhibit operations.
To enable/disable the inhibit function, use the [INHBT
SET] button and [INHBT ALL CLR] button assigned to
the function button section.
When a cross-point button is set to inhibited, the operation
of all cross-point buttons with the same number in the
cross-point button rows are inhibited.
To inhibit a cross-point button
Press and hold the [INHBT SET] button, and press the
target cross-point button to set.
While the [INHBT SET] button is pressed, the inhibited
buttons flash amber.
Notes
• When a cross-point button is inhibited, the button turns
off and the display signal name is not displayed.
• Even when you inhibit a cross-point button, macro
attachment settings are still possible.
• You can inhibit cross-point buttons for each cross-point
assign table using the Home > Setup > Xpt Assign >
Table Button Assign menu (19102.31).
For details about setting inhibit mode, see "Creating
Tables 1 to 14" (page 301).
To release the inhibit setting for a cross-point
button
Press and hold the [INHBT SET] button, and press the
target cross-point button to release.
To release the inhibit setting for all cross-point
buttons
Press and hold the [INHBT SET] button, and press the
[INHBT ALL CLR] button.
Preventing Operation of a Cross-
Point Button Row (Protect Function)
You can temporarily prevent button operations for each
cross-point button row on the cross-point control block.
To enable/disable the protect function, use the [PROT]
button assigned to the function button section.
To protect a cross-point button row
Press the [PROT] button, turning it on, for the target cross-
point button row (1st row to 4th row) to set.
To release the protection setting for a cross-point
button row
Press the [PROT] button, turning it off, for the target cross-
point button row (1st row to 4th row) to release.