User Guide
Machine Types: 7D4C

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo HR630X V2

  • Page 1 HR630X V2 User Guide Machine Types: 7D4C...
  • Page 2 Before using this information and the product it supports, be sure to read and understand the safety information and the safety instructions, which are available at: http://thinksystem.lenovofiles.com/help/topic/safety_documentation/pdf_files.html In addition, be sure that you are familiar with the terms and conditions of the Lenovo warranty for your server, which can be found at: http://datacentersupport.lenovo.com/warrantylookup First Edition (June 2021) ©...
  • Page 3: Table Of Contents

    Safety precautions ... . System board replacement ..102 Remove a hot-swap power supply unit ..© Copyright Lenovo 2021...
  • Page 4 Index ....121 Appendix A. Getting help and technical assistance ..115 HR630X V2 User Guide...
  • Page 5: Safety

    Safety Before installing this product, read the Safety Information. Antes de instalar este produto, leia as Informações de Segurança. 在安装本产品之前,请仔细阅读 Safety Information (安全信息)。 Læs sikkerhedsforskrifterne, før du installerer dette produkt. Lees voordat u dit product installeert eerst de veiligheidsvoorschriften. Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information. Avant d'installer ce produit, lisez les consignes de sécurité.
  • Page 6: Safety Inspection Checklist

    1 & IEC 60950-1, the standard for Safety of Electronic Equipment within the Field of Audio/Video, Information Technology and Communication Technology. Lenovo assumes you are qualified in the servicing of equipment and trained in recognizing hazards energy levels in products. Access to the equipment is by the use of a tool, lock and key, or other means of security, and is controlled by the authority responsible for the location.
  • Page 7: Security Advisories

    • Make sure that the power cord is the correct type. • Make sure that the insulation is not frayed or worn. 3. Check for any obvious non-Lenovo alterations. Use good judgment as to the safety of any non-Lenovo alterations.
  • Page 9: Chapter 1. Introduction

    Chapter 1. Introduction ® Lenovo HR630X V2 server is a 1U rack server that can support up to two Intel Ice Lake processors. The server offers high performance and expansion for various IT workloads. Combining performance and flexibility, the server will be a perfect choice for enterprises of all scales.
  • Page 10 Software RAID: • VROC and VMD HBA (JBOD only) HBA/RAID adapters • 9305-16i HBA 12Gb Hardware RAID (RAID 0/1/10/5/50/6/60) • 9460-8i RAID 12Gb • 930-16i RAID 12Gb Graphics processing unit Support NVIDIA® Tesla® T4 GPU (GPU) HR630X V2 User Guide...
  • Page 11 • 240 HVDC (500 W/750 W/1100 W), Chinese Mainland ONLY CAUTION: Electrical input • Use Lenovo Capacity Planner to calculate the required power capacity for what is configured for your server. More information about Lenovo Capacity Planner is available at: Lenovo Capacity Planner website •...
  • Page 12 – Operating: – ASHRAE Class A2: 8%–80%, maximum dew point: 21°C (70°F) – ASHRAE Class A3: 8%–85%, maximum dew point: 24°C (75°F) – ASHRAE Class A4: 8%–90%, maximum dew point: 24°C (75°F) – Shipment or storage: 8%–90% HR630X V2 User Guide...
  • Page 13: Chapter 2. Server Components

    • “Server models with eight 2.5-inch front drive bays” on page 6 • “Server models with ten 2.5-inch front drive bays” on page 7 • “Server model with four 3.5-inch and/or EDSFF drive bays” on page 8 © Copyright Lenovo 2021...
  • Page 14 Drive status LED Drive activity LED Drive bay filler Diagnostics panel USB 3.0 connector USB 2.0 connector VGA connector Rack latch Drive bays Note: For more information about each component, see “Front components overview” on page 9. HR630X V2 User Guide...
  • Page 15 Server model with ten 2.5-inch drive bays Table 3. Components on the front of the server Drive status LED Drive activity LED Diagnostics panel USB 3.0 connector USB 2.0 connector VGA connector Rack latch Drive bays Note: For more information about each component, see “Front components overview” on page 9. Chapter 2 Server components...
  • Page 16 EDSFF drive bays VGA connector USB 2.0 connectors USB 3.0 connectors Diagnostics panel 3.5-inch drive bays Drive status LED Drive activity LED Note: For more information about each component, see “Front components overview” on page 9. HR630X V2 User Guide...
  • Page 17 Front components overview This section introduces the front components of the server. Diagnostics panel The diagnostics panel provides controls, connectors, and LEDs, and is integrated into front I/O assembly in some models. Figure 1. Diagnostics panel Power button with power status LED You can press the power button to power on the server when you finish setting up the server.
  • Page 18 Solid yellow The drive has an error. The drive is being rebuilt. Blinking yellow (blinking slowly, about one flash per second) Blinking yellow (blinking rapidly, about four The RAID adapter is locating the drive. flashes per second) HR630X V2 User Guide...
  • Page 19 Drive LED Status Description Drive activity LED (left) Solid green The drive is powered but not active. Blinking green The drive is active. Hot-swap drives and drive bays The drive bays on the front and rear of your server are designed for hot-swap drives. The number of the installed drives in your server varies by model.
  • Page 20: Rear View

    • “Server model with three PCIe slots” on page 13 • “Server model with two PCIe slots” on page 14 • “Server model with two hot-swap 2.5-inch rear drive bays and one PCIe slot” on page 15 HR630X V2 User Guide...
  • Page 21 Server model with three PCIe slots The following illustration shows the rear view of server model with three PCIe slots. Depending on the model, your server might look slightly different from the illustration below. Table 5. Components on the rear of the server Ethernet connectors on OCP 3.0 Ethernet adapter Network management interface USB 3.0 connector...
  • Page 22 USB 3.0 connector VGA connector NMI button Power supply 1 Power supply 0 Rear wall bracket PCIe slot 2 PCIe slot 1 Note: For more information about each component, see “Rear components overview” on page 16. HR630X V2 User Guide...
  • Page 23 Server model with two 2.5-inch hot-swap rear drive bays and one PCIe slot The following illustration shows the rear view of the server model with two hot-swap drive bays and one PCIe slot. Depending on the model, your server might look slightly different from the illustration below. Table 7.
  • Page 24 Press this button to force a nonmaskable interrupt (NMI) to the processor. By this way, you can make the operating system halt (such as Windows Blue Screen of Death) and take a memory dump. You might have to use a pen or the end of a straightened paper clip to press the button. HR630X V2 User Guide...
  • Page 25 The hot-swap redundant power supply unit helps you avoid significant interruption to the operation of the system when a power supply unit fails. You can purchase a power supply unit option from Lenovo and install the power supply unit to provide power redundancy without turning off the server.
  • Page 26 Ethernet status LED Description Color Status Ethernet link LED Network link is established. Green None Network link is disconnected. Ethernet activity LED Green Blinking Network link is connected and active. None The server is disconnected from a LAN. HR630X V2 User Guide...
  • Page 27 3 4 5 Power supply LEDs Each hot-swap power supply has three status LEDs. Description Power input • Green: The power supply is connected to the ac power source. • Off: The power supply is disconnected from the ac power source or a power problem occurs. Power output •...
  • Page 28: System Board

    System Board Lift Handle Fan Board Power Connector MCIO 4 Connector MCIO 5 Connector EDSFF Power Connector PSU 1 Connector MCIO 3 Connector MCIO 2 Connector Front Backplane Power Connector PSU 0 Connector Riser 1 Slot HR630X V2 User Guide...
  • Page 29: Parts List

    Tier 1 CRU at your request with no service agreement, you will be charged for the installation. • Tier 2 customer replaceable unit (CRU): You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your server.
  • Page 30 Top cover √ Standard air baffle √ Riser assembly (LP) √ Riser assembly (LP+LP) √ Riser assembly (LP+FH) √ Rearwall bracket √ PCIe adapter √ System board √ RAID super capacitor holder (on √ chassis) HR630X V2 User Guide...
  • Page 31 Table 9. Parts list (continued) Consumable Description Index Tier 1 CRU Tier 2 CRU Structural parts RAID super capacitor holder (in riser √ cage) RAID super capacitor √ OCP 3.0 Ethernet adapter √ Power supply unit √ Power supply unit filler √...
  • Page 32 HR630X V2 User Guide...
  • Page 33: Chapter 3. Server Hardware Setup

    Note: The BMC can place the server in a standby state as an automatic response to a critical system failure. • Start an orderly shutdown using the operating system (if supported by your operating system). • Press the power button to start an orderly shutdown (if supported by your operating system). © Copyright Lenovo 2021...
  • Page 34 • Press and hold the power button for more than 4 seconds to force a shutdown. When in a standby state, the server can respond to remote power-on requests sent to the BMC. For information about powering on the server, see “Power on the server” on page 25. HR630X V2 User Guide...
  • Page 35: Chapter 4. Hardware Replacement Procedures

    • Blue on a component indicates touch points, where you can grip to remove a component from or install it in the server, open or close a latch, and so on. © Copyright Lenovo 2021...
  • Page 36: System Reliability Guidelines

    • While the device is still in its static-protective package, touch it to an unpainted metal surface on the outside of the server for at least two seconds. This drains static electricity from the package and from your body. HR630X V2 User Guide...
  • Page 37: Air Baffle Replacement

    • Remove the device from the package and install it directly into the server without putting it down. If it is necessary to put the device down, put it back into the static-protective package. Never place the device on the server or on any metal surface. •...
  • Page 38: Install The Air Baffle

    S033 CAUTION: Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with metal, which might result in spattered metal, burns, or both. S017 HR630X V2 User Guide...
  • Page 39: Cmos Battery Replacement

    CAUTION: Hazardous moving fan blades nearby. Keep fingers and other body parts away. Attention: • Read “Installation Guidelines” on page 27 to ensure that you work safely. • Power off the server and disconnect all power cords for this task. Procedure Step 1.
  • Page 40 The following tips describe information that you must consider when removing the CMOS battery. • Lenovo has designed this product with your safety in mind. The lithium CMOS battery must be handled correctly to avoid possible danger. If you replace the CMOS battery, you must adhere to the following instructions.
  • Page 41: Install The Cmos Battery

    The following tips describe information that you must consider when installing the CMOS battery. • Lenovo has designed this product with your safety in mind. The lithium battery must be handled correctly to avoid possible danger. If you install the CMOS battery, you must adhere to the following instructions.
  • Page 42 S004 CAUTION: When replacing the lithium battery, use only Lenovo specified part number or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of.
  • Page 43: Front I/O Assembly Replacement

    Figure 8. CMOS battery installation After you finish 1. Complete the parts replacement. See “Complete the parts replacement” on page 110. 2. Use the Setup utility to set the date, time, and any passwords. Front I/O assembly replacement Use this information to remove and install the front I/O assembly. Remove the front I/O assembly Use this information to remove the front I/O assembly.
  • Page 44: Install The Front I/O Assembly

    Touch the static-protective package that contains the front I/O assembly to any unpainted surface on the outside of the server. Then, take the front I/O assembly out of the package and place it on a static-protective surface. Step 2. Install the front I/O assembly. HR630X V2 User Guide...
  • Page 45: Hot-Swap Drive Replacement

    Figure 10. Installation of the front I/O assembly Insert the front I/O assembly into the front chassis. Install the screws to secure the front I/O assembly in place. After you finish 1. Connect the front I/O cables to the system board. 2.
  • Page 46: Install A Hot-Swap Drive

    2. If you are instructed to return the old hot-swap drive, follow all packaging instructions and use any packaging materials that are provided. Install a hot-swap drive Use this information to install a hot-swap drive. About this task HR630X V2 User Guide...
  • Page 47 Attention: • Read “Installation Guidelines” on page 27 to ensure that you work safely. • Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static- sensitive components in their static-protective packages until installation, and handling these devices with an electrostatic-discharge wrist strap or other grounding system.
  • Page 48: Backplane Replacement

    Remove all the installed drives and drive fillers from the drive bays. See “Remove a hot-swap drive” on page 37. Step 3. Grasp the backplane and carefully lift it out of the chassis. Figure 15. Removal of backplane for ten 2.5-inch hot-swap drives Step 4. Disconnect the cables from the backplane. HR630X V2 User Guide...
  • Page 49: Install The Front 2.5-Inch-Drive Backplane

    After you finish If you are instructed to return the old backplane, follow all packaging instructions and use any packaging materials that are provided. Install the front 2.5-inch-drive backplane Use this information to install the backplane for eight or ten 2.5-inch hot-swap drives. About this task The following describes how to install the backplane for ten 2.5-inch hot-swap drives.
  • Page 50: Remove The Front 3.5-Inch-Drive Backplane

    Remove the system fan cage for easier operation. See “Remove a system fan” on page 97. Remove all the installed drives and fillers (if any) from the drive bays. See “Remove a hot-swap drive” on page 37. HR630X V2 User Guide...
  • Page 51: Install The Front 3.5-Inch-Drive Backplane

    Step 2. Remove the backplane from the chassis. Figure 17. 3.5-inch-drive backplane removal Open the release latches that secure the backplane. Rotate the backplane backward slightly to release it from the three pins on the front drive cage. Slightly lift the backplane up. Step 3.
  • Page 52: Remove The 2.5-Inch Rear Drive Backplane

    1. Reinstall all the drives and drive fillers into the drive bays. See “Install a hot-swap drive” on page 38. 2. Complete the parts replacement. See “Complete the parts replacement” on page 110. Remove the 2.5-inch rear drive backplane Use this information to remove the 2.5-inch rear drive backplane. About this task Attention: HR630X V2 User Guide...
  • Page 53 • Read “Installation Guidelines” on page 27 to ensure that you work safely. • Power off the server and disconnect all power cords for this task. • Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static- sensitive components in their static-protective packages until installation, and handling these devices with an electrostatic-discharge wrist strap or other grounding system.
  • Page 54: Install The 2.5-Inch Rear Drive Backplane

    Touch the static-protective package that contains the rear backplane to any unpainted surface on the outside of the server. Then, take the rear backplane out of the package and place it on a static- protective surface. HR630X V2 User Guide...
  • Page 55 Step 2. Align the rear backplane with the rear hot-swap drive cage and lower it into the rear hot-swap drive cage. Figure 21. Rear backplane installation Step 3. Connect the signal cable and the power cable on the rear backplane. Step 4.
  • Page 56: Hot-Swap Rear Drive Assembly Replacement

    Disconnect the hot-swap rear drive cage cables from the system board or the PCIe adapter. Step 4. Hold the two blue touch points and directly lift the hot-swap rear drive cage out of the chassis. Figure 23. Hot-swap rear drive cage removal HR630X V2 User Guide...
  • Page 57: Install The Hot-Swap Rear Drive Assembly

    Step 5. If the rear backplane is reused, remove the rear backplane. See “Remove the 2.5-inch rear drive backplane” on page 44. After you finish If you are instructed to return the old hot-swap rear drive cage, follow all packaging instructions and use any packaging materials that are provided.
  • Page 58 Figure 25. Rear backplane installation Step 4. Connect the signal cable and the power cable on the rear backplane. Step 5. Install the air baffle into the hot-swap rear drive cage as shown. Figure 26. Air baffle installation HR630X V2 User Guide...
  • Page 59: Hot-Swap Power Supply Unit Replacement

    Step 6. Align the pins on the hot-swap rear drive cage with the corresponding hole and slot in the chassis. Then, lower the hot-swap rear drive cage into the chassis until it is fully seated. Figure 27. Hot-swap rear drive cage installation Step 7.
  • Page 60 Damages and losses resulting from inappropriate operations will not be covered by the manufacturer’s warranty. 1. Turn off the server. 2. Disconnect the power cord from the power source. 3. Disconnect the power cord from the power supply unit. HR630X V2 User Guide...
  • Page 61 S035 CAUTION: Never remove the cover on a power supply or any part that has this label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. S019 CAUTION: The power-control button on the device does not turn off the electrical current supplied to the device.
  • Page 62: Remove A Hot-Swap Power Supply Unit

    Figure 28. Hot-swap power supply removal After you finish 1. Install a new power supply or install the power-supply filler to cover the power supply bay. See “Install a hot-swap power supply unit” on page 55. HR630X V2 User Guide...
  • Page 63: Install A Hot-Swap Power Supply Unit

    Important: To ensure proper cooling during normal server operation, both of the power supply bays must be occupied. This means that each bay must have a power supply installed; or one has a power supply installed and the other has a power supply filler installed. 2.
  • Page 64 2. If the server is turned off, turn on the server. Ensure that both the power input LED and the power output LED on the power supply are lit, indicating that the power supply is operating properly. HR630X V2 User Guide...
  • Page 65: Memory Module Replacement

    Memory module replacement Use this information to remove and install a memory module. Remove a memory module Use this information to remove a memory module. About this task Attention: • Read “Installation Guidelines” on page 27 to ensure that you work safely. •...
  • Page 66: Memory Module Installation Rules

    • Minimum memory: – 16 GB using RDIMMs • Maximum memory: – 2 TB using RDIMMs • Type (depending on the model): – TruDDR4 3200, dual-rank, 16 GB/32 GB/64 GB RDIMMs – 128 GB/256 GB DCPMMs HR630X V2 User Guide...
  • Page 67: Install A Memory Module

    Note: The operating speed and total memory capacity depend on the processor model and UEFI settings. The following figure and table help you locate the memory slots and channels on the system board. Figure 33. Memory module locations Table 10. Memory slot and channel identification Channel Slot number...
  • Page 68 Then, take the memory module out of the package and place it on a static-protective surface. Step 2. Locate the required memory module slot on the system board. Note: Ensure that you observe the installation rules and sequence in “Memory module installation rules” on page 58. HR630X V2 User Guide...
  • Page 69: M.2 Adapter And M.2 Drive Replacement

    Step 3. Install the memory module into the slot. Figure 34. Memory module installation Open the retaining clip on each end of the memory module slot. Attention: To avoid breaking the retaining clips or damaging the memory module slots, open and close the clips gently.
  • Page 70: Remove The M.2 Adapter And M.2 Drive

    Procedure Step 1. Remove the top cover. See “Remove the top cover” on page 106. HR630X V2 User Guide...
  • Page 71 Step 2. Remove the M.2 drive from the M.2 adapter. Note: The M.2 adapter you want to remove might be different from the following illustrations, but the removal method is the same. Figure 35. M.2 drive removal Press both sides of the retainer Slide the retainer backward to loosen the M.2 drive from the M.2 adapter.
  • Page 72: Adjust The Retainer On The M.2 Adapter

    Procedure Note: The M.2 adapter you want to adjust might be different from the following illustrations, but the adjustment method is the same. HR630X V2 User Guide...
  • Page 73: Install The M.2 Adapter And M.2 Drive

    Figure 37. M.2 retainer adjustment Step 1. Press both sides of the retainers. Step 2. Move the retainer forward until it is in the large opening of the keyhole. Step 3. Take the retainer out of the keyhole. Step 4. Insert the retainer into the correct keyhole into which the retainer should be installed to accommodate the particular size of the M.2 drive you wish to install.
  • Page 74 Install the M.2 adapter onto the chassis. Figure 39. M.2 adapter installation Align the notch of the M.2 adapter with the pin on the chassis, and then place down the M.2 adapter. Tighten the screw to secure the M.2 adapter. HR630X V2 User Guide...
  • Page 75: Ocp 3.0 Ethernet Adapter Replacement

    Step 5. Install the M.2 drive on the M.2 adapter. Figure 40. M.2 drive installation Insert the M.2 drive at an angle of approximately 30 degrees into the connector. Rotate the M.2 drive down until the notch catches on the lip of the retainer Slide the retainer forward (toward the connector) to secure the M.2 drive into place.
  • Page 76: Install The Ocp 3.0 Ethernet Adapter

    Touch the static-protective package that contains the OCP 3.0 Ethernet adapter to any unpainted surface on the outside of the server. Then, take the OCP 3.0 Ethernet adapter out of the package and place it on a static-protective surface. HR630X V2 User Guide...
  • Page 77 Step 2. Attach the OCP 3.0 Ethernet adapter label that comes with this option on the rear of the server. Figure 42. OCP 3.0 Ethernet adapter label installation Chapter 4 Hardware replacement procedures...
  • Page 78: Pcie Adapter Replacement

    The PCIe adapter can be an Ethernet adapter, a host bus adapter (HBA), a PCIe RAID adapter, a PCIe interposer adapter, a PCIe solid-state drive, a PCIe GPU, and any other supported PCIe adapter. Notes: • Depending on the specific type, the PCIe adapter might look different from the illustrations in this topic. HR630X V2 User Guide...
  • Page 79: Remove A Pcie Adapter

    • Use any documentation that comes with the PCIe adapter and follow those instructions in addition to the instructions in this topic. Remove a PCIe adapter Use this information to remove a PCIe adapter. About this task Attention: • Read “Installation Guidelines” on page 27 to ensure that you work safely. •...
  • Page 80: Install A Pcie Adapter

    LP-FH riser assembly is used as an example. Step 4. Connect the cables to the PCIe adapter in the riser assembly. After you finish 1. Reinstall the riser assembly. See “Install a riser card” on page 95. HR630X V2 User Guide...
  • Page 81: Processor And Heat Sink Replacement

    2. Complete the parts replacement. See “Complete the parts replacement” on page 110. Processor and heat sink replacement Use this information to remove and install a processor and heat sink assembly. • “Remove a standard heat sink” on page 73 •...
  • Page 82: Remove A T-Shaped Heat Sink

    • It may take some time for the heat sink to cool down after the system has been powered off. • The heat sink is necessary to maintain proper thermal conditions for the processor. Do not power on the server with the heat sink removed. Procedure HR630X V2 User Guide...
  • Page 83: Remove A Processor

    Step 1. Remove the top cover. See “Remove the top cover” on page 106. Step 2. Remove the air baffle. See “Remove the air baffle” on page 29. Step 3. Remove any parts and disconnect any cables that might impede your access to the heat sink and processor.
  • Page 84: Install A Processor

    Notes: • All processors on the system board must have the same speed, number of cores, and frequency. • Before you install a new processor, update your system firmware to the latest level. HR630X V2 User Guide...
  • Page 85: Install A Standard Heat Sink

    • Optional devices available for your system might have specific processor requirements. Procedure Figure 49. Processor installation Step 1. Slide the processor carrier into the rail frame. Step 2. Push the rail frame down until the blue latches lock into place. Step 3.
  • Page 86 After you finish 1. Install the air baffle. See “Install the air baffle” on page 30. 2. Install any parts that you have removed. 3. Complete the parts replacement. See “Complete the parts replacement” on page 110. HR630X V2 User Guide...
  • Page 87: Install A T-Shaped Heat Sink

    Install a T-shaped heat sink Use this information to install a T-shaped heat sink. About this task Attention: • Read “Installation Guidelines” on page 27 to ensure that you work safely. • Power off the server and disconnect all power cords for this task. •...
  • Page 88: Rack Latches Replacement

    Use this information to remove and install the rack latches. Remove the rack latches Use this information to remove the rack latches. About this task Attention: Read “Installation Guidelines” on page 27 to ensure that you work safely. Procedure HR630X V2 User Guide...
  • Page 89 Step 1. Use a flat-blade screwdriver to remove the ID label plate on the right rack latch and place it in a safe place. Figure 54. ID label plate removal Step 2. On each side of the server, remove the two screws that secure the rack latch. Figure 55.
  • Page 90: Install The Rack Latches

    Touch the static-protective package that contains the rack latches to any unpainted surface on the outside of the server. Then, take the rack latches out of the package and place them on a static- protective surface. HR630X V2 User Guide...
  • Page 91 Step 2. On each side of the server, align the rack latch with the pin on the chassis. Then, press the rack latch onto the chassis and slightly slide it forward as shown. Figure 57. Rack latch installation Step 3. Install the two screws to secure the rack latch on each side of the server.
  • Page 92: Raid Super Capacitor Module Replacement

    RAID super capacitor module replacement The RAID super capacitor module protects the cache memory on the installed RAID adapter. You can purchase a RAID super capacitor module from Lenovo. Use this information to remove and install a RAID super capacitor module.
  • Page 93: Remove The Raid Super Capacitor Module On The Chassis

    Super capacitor on the chassis Super capacitors in the air baffle Super capacitors in the riser 1 slot Figure 60. RAID super capacitor module location Remove the RAID super capacitor module on the chassis Use this information to remove the RAID super capacitor module on the chassis. About this task Attention: •...
  • Page 94 Open the retention clip on the holder of the RAID super capacitor module. Take the RAID super capacitor module out of the holder. Step 4. Remove the RAID super capacitor module holder as shown if necessary. Figure 62. RAID super capacitor module holder removal After you finish HR630X V2 User Guide...
  • Page 95: Install The Raid Super Capacitor Module On The Chassis

    If you are instructed to return the old RAID super capacitor module, follow all packaging instructions and use any packaging materials that are provided. Install the RAID super capacitor module on the chassis Use this information to install the RAID super capacitor module on the chassis. About this task Attention: •...
  • Page 96 Figure 65. Installation of the RAID super capacitor module on the chassis Open the retention clip on the holder. Put the RAID super capacitor module into the holder and press it down to secure it into the holder. HR630X V2 User Guide...
  • Page 97: Remove The Raid Super Capacitor Module On The Air Baffle

    After you finish 1. Connect the super capacitor module to an adapter with the extension cable that comes with the super capacitor module. 2. Complete the parts replacement. See “Complete the parts replacement” on page 110. Remove the RAID super capacitor module on the air baffle Use this information to remove the RAID super capacitor module on the air baffle.
  • Page 98: Install The Raid Super Capacitor Module On The Air Baffle

    3. Complete the parts replacement. See “Complete the parts replacement” on page 110. Remove the RAID super capacitor module on the riser Use this information to remove the RAID super capacitor module on the riser. HR630X V2 User Guide...
  • Page 99: Install The Raid Super Capacitor Module On The Riser

    About this task Attention: • Read “Installation Guidelines” on page 27 to ensure that you work safely. • Power off the server and disconnect all power cords for this task. • Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static- sensitive components in their static-protective packages until installation, and handling these devices with an electrostatic-discharge wrist strap or other grounding system.
  • Page 100: Riser Card Replacement

    There are different types of riser assembly configurations. The removal or installation procedure of the riser card is similar for all types of riser assembly. The following takes the LP-FH riser assembly as an example. Remove a riser card Use this information to remove a riser card. HR630X V2 User Guide...
  • Page 101 About this task The riser assembly you want to remove might be different from the following illustrations, but the removal method is the same. The following takes the LP-FH riser assembly as an example. Attention: • Read “Installation Guidelines” on page 27 to ensure that you work safely. •...
  • Page 102 1. If you are instructed to return the old riser card, follow all packaging instructions and use any packaging materials that are provided. 2. Remove the rear wall bracket if you would like to install a non-LP-FH riser assembly. HR630X V2 User Guide...
  • Page 103: Install A Riser Card

    Figure 72. Rear wall bracket removal Install a riser card Use this information to install a riser card. About this task The riser assembly you want to install might be different from the following illustrations, but the installation method is the same. The following takes the LPFH riser assembly as an example. Attention: •...
  • Page 104 Step 3. If necessary, reinstall the PCIe adapters on the riser card. See “Install a PCIe adapter” on page 72. Then, refer to your note to reconnect any cables of the PCIe adapters on the riser card. HR630X V2 User Guide...
  • Page 105: System Fan Replacement

    Step 4. Position the riser assembly on the chassis. Align the plastic clip and two pins on the bracket with the guide pin and two holes on the chassis and align the riser card with the riser slot on the system board.
  • Page 106: Install A System Fan

    Install a system fan Use this information to install a system fan. You can install a hot-swap fan without powering off the server, which helps you avoid significant interruption to the operation of the system. About this task HR630X V2 User Guide...
  • Page 107 S033 CAUTION: Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with metal, which might result in spattered metal, burns, or both. S017 CAUTION: Hazardous moving fan blades nearby. Keep fingers and other body parts away. Attention: •...
  • Page 108: Fan Board Replacement

    5. Disconnect any cables that might impede your access to the fan board. Before cable disconnection, record where the cables are connected to the system board. To remove the fan board, complete the following steps: Watch the procedure. A video of the removal process is available: HR630X V2 User Guide...
  • Page 109: Install The Fan Board

    • Youtube: https://www.youtube.com/playlist?list=PLYV5R7hVcs-DY1RaWHYM4xDloAwuBQHR0 • Youku: http://list.youku.com/albumlist/show/id_52339628 Figure 77. Fan board removal Step 1. Remove the three screws from the fan board. Step 2. Hold the lift handle as arrow indicated, and slide the fan board toward the right side of the server as arrow indicated at the same time.
  • Page 110: System Board Replacement

    3. Complete the parts replacement. See “Complete the parts replacement” on page 110. System board replacement Use this information to remove and install the system board. S017 CAUTION: Hazardous moving fan blades nearby. Keep fingers and other body parts away. S012 HR630X V2 User Guide...
  • Page 111: Remove The System Board

    CAUTION: Hot surface nearby. Remove the system board Use this information to remove the system board. About this task A system board, also known as the motherboard, provides different connectors or slots to connect different components or peripherals of the system for communication. If the system board fails, it must be replaced. Attention: •...
  • Page 112: Install The System Board

    Touch the static-protective package that contains the system board to any unpainted surface on the outside of the server. Then, take the system board out of the package and place it on a static- protective surface. HR630X V2 User Guide...
  • Page 113 Step 2. Install the system board to the server. Figure 80. System board installation Hold the lift handle and the release pin at the same time to lower the system board onto the chassis. Slide the system board to the rear of the server until the system board snaps into position. Ensure that: •...
  • Page 114: Top Cover Replacement

    Use this information to remove the top cover. About this task S033 CAUTION: Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with metal, which might result in spattered metal, burns, or both. HR630X V2 User Guide...
  • Page 115 S014 CAUTION: Hazardous voltage, current, and energy levels might be present. Only a qualified service technician is authorized to remove the covers where the label is attached. Attention: • Read “Installation Guidelines” on page 27 to ensure that you work safely. •...
  • Page 116: Install The Top Cover

    Use this information to install the top cover. About this task S033 CAUTION: Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with metal, which might result in spattered metal, burns, or both. HR630X V2 User Guide...
  • Page 117 S014 CAUTION: Hazardous voltage, current, and energy levels might be present. Only a qualified service technician is authorized to remove the covers where the label is attached. Attention: • Read “Installation Guidelines” on page 27 to ensure that you work safely. •...
  • Page 118: Complete The Parts Replacement

    1. Ensure that all components have been reassembled correctly and that no tools or loose screws are left inside your server. 2. Properly route and secure the cables in the server. 3. If you have removed the top cover, reinstall it. See “Install the top cover” on page 108. HR630X V2 User Guide...
  • Page 119 4. Reconnect external cables and power cords to the server. Attention: To avoid component damage, connect the power cords last. 5. Update the server configuration if necessary. Chapter 4 Hardware replacement procedures...
  • Page 120 HR630X V2 User Guide...
  • Page 121: Chapter 5. Problem Determination

    Use the information in this section to isolate and resolve issues that you might encounter while using your server. To isolate a problem, you should typically begin with the event log of the application that is managing the server. © Copyright Lenovo 2021...
  • Page 122 HR630X V2 User Guide...
  • Page 123: Appendix A. Getting Help And Technical Assistance

    Appendix A. Getting help and technical assistance If you need help, service, or technical assistance or just want more information about Lenovo products, you will find a wide variety of sources available from Lenovo to assist you. On the World Wide Web, up-to-date information about Lenovo systems, optional devices, services, and support are available at: http://datacentersupport.lenovo.com...
  • Page 124: Collecting Service Data

    Collecting service data To clearly identify the root cause of a server issue or at the request of Lenovo Support, you might need collect service data that can be used for further analysis. Service data includes information such as event logs and hardware inventory.
  • Page 125: Appendix B. Notices

    Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead.
  • Page 126: Trademarks

    If Lenovo determines that the levels of particulates or gases in your environment have caused damage to the device, Lenovo may condition provision of repair or replacement of devices or parts on implementation of appropriate remedial measures to mitigate such environmental contamination.
  • Page 127: Electronic Emission Notices

    Electronic emission notices When you attach a monitor to the equipment, you must use the designated monitor cable and any interference suppression devices that are supplied with the monitor. Additional electronic emissions notices are available at: http://thinksystem.lenovofiles.com/help/index.jsp Appendix B. Notices...
  • Page 128 HR630X V2 User Guide...
  • Page 129: Index

    RAID super capacitor module on the air baffle installing RAID super capacitor module on the chassis removing RAID super capacitor module on the riser front I/O assembly rear backplane installing riser card removing standard heat sink © Copyright Lenovo 2021...
  • Page 130 RAID super capacitor module on the chassis safety inspection checklist installing security advisories removing server setup RAID super capacitor module on the riser server setup procedure installing service and support removing before you call HR630X V2 User Guide...
  • Page 131 T-shaped heat sink support web page, custom installing system board removing installing telecommunication regulatory statement removing top cover replacing installing system board components removing system fan replacing installing trademarks removing © Copyright Lenovo 2021...
  • Page 132 HR630X V2 User Guide...