Frequency Converter - Electrolux Smart Service Manual

Boiling pan
Table of Contents

Advertisement

Frequency converter (Yaskawa brand) Until June 2008
Although the Frequency converter is a complex product we refer to the delivered Operation manual by the
supplier of the Frequency converter .
The values in this manual refering to Frequency converter of the Yaskawa brand.
The Operation manual can be ordered from supplier of the Frequency converter BEVI co.
Factory set-up
Variomix 50-150
Pos.
Value
Up to REV.* From Rev.*
UCP04V03 UCP04V11C
n01
1
1
n02
1
1
n03
2
2
n09
54
108
n13
10
10
n15
10
10
n16
3,0
2,0
n17
3,0
2,0
n32
4,0
4,0
7,2
7,2
n33
1
1
n40
0
0
n01
0
0
Variomix 200-300
Pos.
Value
Up to REV.* From Rev.*
UCP04V03 UCP04V11C
n01
1
1
n02
1
1
n03
2
2
n09
54,0
108
n12
25,0
25,0
n13
207
207
n15
18
18
n16
3,0
2,0
n17
3,0
2,0
n32
5,5
5,5
n33
1
1
n40
0
0
n01
0
0
* Shown on the display when starting the boiling pan.
14
Description
Programming & read
Command selection
Frequency ref. selection
max. output frequency (Hz)
Mid. output (V)
Min. output (V)
Acceleration time (S)
Retardation time
motor rated current (A)
(50L)
(100, 150L)
motor selection
Failure signal
Read
Description
Programming & read
Command selection
Frequency ref. selection
max. output frequency (Hz)
Mid. output (Hz)
Mid. output (V))
Min. output (V)
Acceleration time (S)
Retardation time
motor rated current (A)
motor selection
Failure signal
Read
Promix 100-150
Pos.
Value
n01
1
n02
1
n03
2
n05
1
n09
61,0
n12
15,0
n13
130
n15
18
n16
3,0
n17
3,0
n32
5,5
n33
1
n40
0
n01
0
Promix 200-30
Pos.
Value
n01
1
n02
1
n03
2
n05
1
n09
63,0
n12
25,0
n13
207
n15
18
n16
3,0
n17
3,0
n32
7,2
n33
1
n40
0
n01
0
Description
Programming & read
Command selection
Frequency ref. selection
Reverse run forbidden
max. output frequency (Hz)
Mid. frequency (Hz)
Mid. output (V)
Min. output (V)
Acceleration time (S)
Retardation time
motor rated current (A)
motor selection
Failure signal
Read
Description
Programming & read
Command selection
Frequency ref. selection
Reverse run forbiden
max. output frequency (Hz)
Mid. frequency (Hz)
Mid. output (V))
Min. output (V)
Acceleration time (S)
Retardation time
motor rated current (A)
motor selection
Failure signal
Read

Hide quick links:

Advertisement

Table of Contents
loading