6 LCCF_EnetScanner block

LCCF_EnetScanner block
6
6.1

Parameters

The LCCF_EnetScanner has been designed to require a minimum of parameters
to make its use as easy as possible. Still a minimum external configuration is
necessary, which is explained in the following chapter.
A call to the LCCF_EnetScanner block requires an instance DB to store operation
relevant data internally as shown in the below figure.
Table 6-1: block call to "LCCF_EnetScanner"
The instance DB is generated automatically by the TIA Portal, when you place the
call to the block. In this application example the instance DB is named
"InstScanner".
Besides the instance DB the other shown parameters are necessary and are
explained in the below table.
Table 6-2: Parameter of the LCCF_EnetScanner block
Name
enable
interface
adapters
EtherNet/IP Scanner
Entry-ID: 109782314,
V1.1.0,
LAD
Direction
Data Type
Input
BOOL
Input
HW_ANY
InOut
Array[*] of
LCCF_typeEnetAdaptConfig
04/2021
SCL
Description
Rising edge enables the
functionality of the block. Any
previously reported fault will be
cleared, and conditions re-
evaluated.
Falling edge shuts the block
down and stops any
communications.
Hardware Identifier of the
interface to use for the
communication. This typically
uses a system defined
constant.
It is possible to use any "Open
User Communication"
supporting interface. This
includes Industrial Ethernet
CMs and CPs
List of configured adapters to
exchange data with. Each array
element represents one
EtherNet/IP adapter and is of
type
36