5.3 ADVANCED SETTINGS
Event masks have two possible settings, YES or NO. If an action (e.g. the trip of a protection function) is set as
YES, when the trip takes place an event will be generated. If it is set as NO, no event will be generated.
EVENT MASKS
37 Pickup/Drop out
46 Pickup/Drop out
48 Pickup/Drop out
49 Pickup/Drop out
50P Pickup/Drop out
50G Pickup/Drop out
51P Pickup/Drop out
51G Pickup/Drop out
87R Pickup/Drop out
37 Inhibition activation/deactivation
46 Inhibition activation/deactivation
48 Inhibition activation/deactivation
49 Inhibition activation/deactivation
50P Inhibition activation/deactivation 50P Inhibition (by DI)
50G Inhibition activation/deactivation 50G Inhibition (by DI)
51P Inhibition activation/deactivation 51P Inhibition (by DI)
5
51G Inhibition activation/deactivation 51G Inhibition (by DI)
87R Inhibition activation/deactivation 87R Inhibition (by DI)
Inhibition activation / deactivation by
digital input
37 Function trip
46 Function trip
48 Function trip
49 Function trip
50P Function trip
50G Function trip
51P Function trip
51G Function trip
87R Function trip
Trip by stop
Function 66 Operation
General Trip
Protection status: in service/out of
service
Digital output1 active/non active
Digital output 2 active/non active
Digital output 3 active/non active
Digital output 4 active/non active
Digital input 1 active/non active
Digital input 2 active/non active
Settings change disabled by digital
input
Trip operation by digital input
Trip operation by command
Auxiliary digital output latch reset
Emergency Reset
Close Breaker
5-20
ENERVISTA MII PC
EVENT MASKS
37 Pickup
46 Pickup
48 Pickup
49 Pickup
50P Pickup
50G Pickup
51P Pickup
51G Pickup
87R Pickup
37 Inhibition (by DI)
46 Inhibition (by DI)
48 Inhibition (by DI)
49 Inhibition (by DI)
Trip inhibition by DI
37 Trip
46 Trip
48 Trip
49 Trip
50P Trip
50G Trip
51P Trip
51G Trip
87R Trip
Trip by stop
Operation 66
General Trip
Protection status
Output 1
Output 2
Output 3
Output 4
Digital input 1
Digital input 2
Settings change disabled
Trip operation by input
Trip operation by com.
Reset latch aux
EMER
Close Breaker
MIGII Digital Protection for Electrical Machines

5.3.12 EVENTS AND OSCILLOGRAPHY MASKS

DEFAULT
RANGE
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
YES
Y/N
5 SETTINGS
STEP
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
GEK-113188A

Advertisement

Table of Contents
loading

Table of Contents