Current vs. Voltage

Table 1-2, VL6000 Beam Luminaire - Current vs. Voltage (1500W Lamp)
Total Luminaire Current is calculated with the lamp on and all motors sequencing.
WARNING: It is the responsibility of the user to adequately protect supply source with a correct size and type circuit breaker and not
overload circuits. AVERTISSEMENT: Il est de la responsibilité de l'utilisateur de protéger adéquatement la source d'alimentation avec une
taille correcte et le disjoncteur de type et surchargez pas les circuits.

Connecting Data

A maximum of 32 luminaires may be connected in any one DMX data link.
Note: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require fewer luminaires on a single data
link path. Consult your console documentation for more information.
To connect power and data:
Step
1. Connect data cable from console to first luminaire in chain at DATA IN connector.
Step
2. If required, connect additional data cables from DATA THRU connectors to DATA IN connectors of remaining luminaires in
Step
3. At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires and other devices on the
AC In
Data In
Step
4. Connect AC Input Cable connector to power input source.
Step
5. Dress AC input and data cables and secure them so that they will not interfere with luminaire head and yoke movement.
7
L
Q
EAM
UMINAIRE
UICK
Table 1-2: VL6000 Beam Luminaire - Current vs. Voltage (1500W Lamp)
AC Voltage @ 60Hz
200V
210V
220V
230V
240V
link.
same DMX chain may not function properly without termination.)
Data Thru
VL6000 Beam Luminaire Channel Requirements*
DMX512 Channels
23 Channels
*As set by the luminaire's menu system.
S
G
TART
UIDE
provides the luminaire's current draw at specific voltages.
Total Luminaire Current (Motor + Lamp Current)
AC In
Description
16-Bit Mode (default)
**DMX terminator required for last fixture on DMX line.
Figure 3: Data Link
27 A p r i l 2 0 1 7
10.5A
10.1A
9.7A
9.3A
8.9A
AC In
Data Thru
Menu Display
16
0 2 . 9 7 0 8 . 0 0 0 1
Termination**