en | Installing the Roof Parapet and Pipe Mounts
Power Supply Box Connections
The following figure is a detailed illustration of the Roof or Pipe Mount Power Supply Box,
which includes the fuse specifications.
Figure 10.3: Power Supply Box Connections
1
2
3
4
Warning!
Fuse replacement by qualified service personnel only. Replace with same type fuse.
!
Fuse Specifications
Volts
24 V
115 V
230 V
The following table lists the Power Supply Box connectors:
No.
Connector
Ground
2021-03 | 1.2 |
P101
CONTROL
CONTROL
LINE NC NEUT
IN/OUT
TO DOM E
1 2 3
P106
GND
GND
GND
T XD RXD
XD
XD
C+ C-
GND
GND
GND
6 5 4 3 2 1
6 5 4 3 2 1
6 5 4 3 2 1
Ground Screw
Transformer (115/230 VAC Modes)
In/Out to camera
24 VAC to Dome Interface Board
XF101 Mains
XF102 Camera
T 5.0 A
T 2.0 A
T 1.6 A
T 2.0 A
T 0.8A
T 2.0 A
Pin 1
Pin 2
Grounding Screw
J102
J102
J102
J102
(LED)
O DOM
O DOM
P105
T XD RXD
XD
XD
C+ C-
5
Power In
6
In/Out; 1/2 in. (15 mm) NPS Fitting
7
Power In; 3/4 in. (20 mm) NPS Fitting
8
Control Data and Video In/Out; 3/4 in. (20 mm)
NPS Fitting
XF103 Heater
T 3.15 A
T 3.15 A
T 3.15 A
Pin 3
Pin 4
Installation Manual
AUTODOME IP starlight 7000i
Pin 5
Pin 6