Maintenance

Read the section'SAFETY INFORMATION' first.
10.1
TEST THE 'ELCB' REGULARLY
(This procedure is highly recommended test at
least once a month)
Turn on the electricityand water supply, both RED
(HEATER) and Green (ELCB) Indicators will light
up if the Temperature Control Knob is in 'ON'
position. Press the ELCB Test Button, both
HEATER and ELCB Indicators should go off. Press
the Rest Button to resume the electricity supply.
10.2
CLEAN THE FILTER REGULARLY
Clean the Mesh Filter regualrly to prevent blockage.
(Fig. 10) Remove the Built-in- Filter by turning its cap
anticlockwise. Whenever need to flush the internal
stainer with water to removes any trapped sediments.
Whenver fixing back the Buily-in Filter, beware of the
alignment of Internal Strainer. Use the protruded
guideline within Stop Valve to position the Internal
Strainer.
ʼn
IJ ⁄ ⁄
OPEN
INTERNAL
STRAINER
BUILT-IN FILTER
9
MESH FILTER
WARNING!
10.3
If the HEATER Indicator does not go off
when you press the ELCB Test Button, switch
OFF the mains supply and contact Beko Call
Centre for repair service. NEVER try to repair
the unit by yourself.
10.4
CLEANING PRECAUTION!
Do not use thinner, alcohol, petrol or any other
organic solutions to clean the set. Use only
damped cloth with mild detergent.
FLOW REGULATOR
CLOSE
OPEN
CLOSE
13 / EN